  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137U9776

VACON 

NXA04605-A0T02SG-A1A2D7B5E9 137U9776 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U9776 and type code NXA04605-A0T02SG-A1A2D7B5E9+UGRD+ARFIF106+GSNT+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137U8940

VACON 

NXA02615-A0T02SG-A1A2000000 137U8940 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U8940 and type code NXA02615-A0T02SG-A1A2000000+ARFIFF05 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Rectifier Unit 137U8723

VACON 

NXN06506-X0T0SSV-0000000000 137U8723 – VACON NXP Common DC Bus Rectifier Unit, 525-690V, IP00

The VACON NXP Common DC Bus rectifier unit with order code 137U8723 and type code NXN06506-X0T0SSV-0000000000+EMAR is a 650 A, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus Brake Chopper Unit 137U8541

VACON 

NXB01405-A0T08SV-A1A2000000 137U8541 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137U8541 and type code NXB01405-A0T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137U8184

VACON 

NXA02615-A0T02SG-A1A2000000 137U8184 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U8184 and type code NXA02615-A0T02SG-A1A2000000+ARFIF106+GSSE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137U8118

VACON 

NXA02615-A0T02SG-A1A2D700E9 137U8118 – VACON NXP Common DC Bus Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U8118 and type code NXA02615-A0T02SG-A1A2D700E9+ARFIFF03 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137U8117

VACON 

NXA09206-A0T02SG-A1A2D700E9 137U8117 – VACON NXP Common DC Bus Active Front End Unit, 1067 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U8117 and type code NXA09206-A0T02SG-A1A2D700E9+ARFIFF03 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U7690

VACON 

NXA10306-G0T02SG-A1A2B50000 137U7690 – VACON NXP Common DC Bus Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U7690 and type code NXA10306-G0T02SG-A1A2B50000 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137U7330

VACON 

NXA03256-A0T02SG-A1A2B500E5 137U7330 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U7330 and type code NXA03256-A0T02SG-A1A2B500E5+DLDE is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137U7488

VACON 

NXA04605-A0T02SG-A1A2B50000 137U7488 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U7488 and type code NXA04605-A0T02SG-A1A2B50000+GSNT+GADN+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137U7093

VACON 

NXA11505-A0T02SG-A100000000 137U7093 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137U7093 and type code NXA11505-A0T02SG-A100000000 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 137U7325

VACON 

NXB02615-A0T08SG-A1AFA4D200 137U7325 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137U7325 and type code NXB02615-A0T08SG-A1AFA4D200 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...