<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACON® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Choose a range

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137N1931

VACON 

NXA04605-A0T02SG-A1A2D7B5E9 137N1931 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N1931 and type code NXA04605-A0T02SG-A1A2D7B5E9+ARFIFF05+DLFR+EMAR is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 137N2499

VACON 

NXB04605-A0T08SG-A1A20000E9 137N2499 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137N2499 and type code NXB04605-A0T08SG-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137N1421

VACON 

NXA04605-A0T02SG-ANA200B5E9 137N1421 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N1421 and type code NXA04605-A0T02SG-ANA200B5E9+GSNT+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137N1777

VACON 

NXB00725-G2T08SV-A1A30000E9 137N1777 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 137N1777 and type code NXB00725-G2T08SV-A1A30000E9+QGLM+FL26+DLCN+GADN is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137N1313

VACON 

NXB02055-A0T08SG-A1A20000E9 137N1313 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137N1313 and type code NXB02055-A0T08SG-A1A20000E9+FL23+DLDE is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137N1024

VACON 

NXA03256-A0T02SG-A1A2000000 137N1024 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N1024 and type code NXA03256-A0T02SG-A1A2000000+FL23 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137N0935

VACON 

NXB04166-A0T08SG-A1A20000CP 137N0935 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137N0935 and type code NXB04166-A0T08SG-A1A20000CP is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137N0933

VACON 

NXA10306-A0T02SG-A1A2D7CP00 137N0933 – VACON NXP Common DC Bus Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N0933 and type code NXA10306-A0T02SG-A1A2D7CP00+GRID+ARFIF106 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137N0925

VACON 

NXA13005-A0T02SG-A1A2B500E9 137N0925 – VACON NXP Common DC Bus Active Front End Unit, 874 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N0925 and type code NXA13005-A0T02SG-A1A2B500E9+ARFIFF05+DLFR is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137N0932

VACON 

NXB02055-A0T08SG-A1A20000CP 137N0932 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137N0932 and type code NXB02055-A0T08SG-A1A20000CP is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137N0854

VACON 

NXA03256-A0T02SG-A1A2D7D2EC 137N0854 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N0854 and type code NXA03256-A0T02SG-A1A2D7D2EC+FL24+GRID+ARFIF106+DLPL is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137N0795

VACON 

NXA04605-A0T02SG-A8A2D7B5E9 137N0795 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N0795 and type code NXA04605-A0T02SG-A8A2D7B5E9+GSNT+GADN+LPC2+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
  • Previous
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • Next