<
<
  • Search

VACON NXP Air Cooled 380-500 V

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

View as:
Sidebar
VACON NXP Air Cooled AC drive, frame FR08, IP21

VACON 

NXP01685-A2H1SSV-A1A3A500E3 137N1220 – VACON NXP Air Cooled AC Drive, 90 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N1220 and type code NXP01685-A2H1SSV-A1A3A500E3+QGLM+FL21+DINS+DLFI is a 90 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Air Cooled AC drive, frame FR10, IP00

VACON 

NXP04605-A0T0SOB-A1AFB40000 137N1228 – VACON NXP Air Cooled AC Drive, 250 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N1228 and type code NXP04605-A0T0SOB-A1AFB40000+FNP02V197+FL23+DLDE is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00055-A2C2SSV-A1A20000E5 137N1219 – VACON NXP Air Cooled AC Drive, 2.2 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N1219 and type code NXP00055-A2C2SSV-A1A20000E5 is a 2.2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 5...
VACON NXP Air Cooled AC drive, frame FR06, IP21

VACON 

NXP00455-A2T1SSV-A1A2B4B200 137N1173 – VACON NXP Air Cooled AC Drive, 22 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N1173 and type code NXP00455-A2T1SSV-A1A2B4B200 is a 22 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It is rated 45...
VACON NXP Air Cooled AC drive, frame FR08, IP54

VACON 

NXP02055-A5H1SSV-A1A3000000 137N1151 – VACON NXP Air Cooled AC Drive, 110 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N1151 and type code NXP02055-A5H1SSV-A1A3000000+QGLM+FL24+DPAP+DLPL is a 110 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR08...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00315-A2H1SSV-A1AF00CI00 137N1182 – VACON NXP Air Cooled AC Drive, 15 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N1182 and type code NXP00315-A2H1SSV-A1AF00CI00 is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is rated 31...
VACON NXP Air Cooled AC drive, frame FR07, IP21

VACON 

NXP01055-A2T0SSV-A1A2B40000 137N1176 – VACON NXP Air Cooled AC Drive, 55 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N1176 and type code NXP01055-A2T0SSV-A1A2B40000 is a 55 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00125-A2T1SSV-A1A2B40000 137N1213 – VACON NXP Air Cooled AC Drive, 5.5 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N1213 and type code NXP00125-A2T1SSV-A1A2B40000+FL21+DLFI is a 5.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00055-A2H1SSV-A1A300E600 137N1184 – VACON NXP Air Cooled AC Drive, 2.2 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N1184 and type code NXP00055-A2H1SSV-A1A300E600 is a 2.2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 5...
VACON NXP Air Cooled AC drive, frame FR10, IP21

VACON 

NXP03855-A2L0OSB-A1A2B20000 137N1193 – VACON NXP Air Cooled AC Drive, 200 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N1193 and type code NXP03855-A2L0OSB-A1A2B20000 is a 200 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR04, IP54

VACON 

NXP00055-A5H1SSV-A1A2000000 137N1199 – VACON NXP Air Cooled AC Drive, 2.2 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N1199 and type code NXP00055-A5H1SSV-A1A2000000+DPAP+DLFR is a 2.2 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR04 configuration. It...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00095-A2H1SSV-ALA3A5E5B4 137N1183 – VACON NXP Air Cooled AC Drive, 4 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N1183 and type code NXP00095-A2H1SSV-ALA3A5E5B4 is a 4 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 9 A...
  • Previous
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • Next