VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

View as:
Sidebar
VACON NXP Air Cooled AC drive, frame FR10, IP00

VACON 

NXP05205-A0N0SSB-000000E500 137N2606 – VACON NXP Air Cooled AC Drive, 250 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N2606 and type code NXP05205-A0N0SSB-000000E500+FL23+DNOT+DLDE is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration...
VACON NXP Air Cooled AC drive, frame FR08, IP54

VACON 

NXP01405-A5T1SSV-A1A2A4B100 137N2621 – VACON NXP Air Cooled AC Drive, 75 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N2621 and type code NXP01405-A5T1SSV-A1A2A4B100+DPAP+DLIT is a 75 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR08 configuration. It...
VACON NXP Air Cooled AC drive, frame FR08, IP21

VACON 

NXP01405-A2T0SSV-A1A3B100E9 137N2598 – VACON NXP Air Cooled AC Drive, 75 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N2598 and type code NXP01405-A2T0SSV-A1A3B100E9 is a 75 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR07, IP21

VACON 

NXP00875-A2T0SSV-A1A3000000 137N2600 – VACON NXP Air Cooled AC Drive, 45 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N2600 and type code NXP00875-A2T0SSV-A1A3000000+QGLM is a 45 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It is...
VACON NXP Air Cooled AC drive, frame FR11, IP00

VACON 

NXP05905-A0T0SSG-A1A3B100E9 137N2597 – VACON NXP Air Cooled AC Drive, 315 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N2597 and type code NXP05905-A0T0SSG-A1A3B100E9 is a 315 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR11 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR10, IP54

VACON 

NXP03855-A5T0PSB-A1A20000E9 137N2588 – VACON NXP Air Cooled AC Drive, 200 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N2588 and type code NXP03855-A5T0PSB-A1A20000E9+DPAP+GAAB is a 200 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC drive, frame FR10, IP54

VACON 

NXP03855-A5T0PSB-A1A20000E9 137N2587 – VACON NXP Air Cooled AC Drive, 200 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N2587 and type code NXP03855-A5T0PSB-A1A20000E9+DPAP+GANK is a 200 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC drive, frame FR09, IP54

VACON 

NXP02615-A5T0SSG-A1A20000E9 137N2586 – VACON NXP Air Cooled AC Drive, 132 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N2586 and type code NXP02615-A5T0SSG-A1A20000E9+QGLM+DPAP+GALR is a 132 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR09 configuration...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00035-A2H1SSV-A1A300D6E5 137N2579 – VACON NXP Air Cooled AC Drive, 1.1 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N2579 and type code NXP00035-A2H1SSV-A1A300D6E5+FL21+DLFI is a 1.1 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It...
VACON NXP Air Cooled AC drive, frame FR10, IP00

VACON 

NXP03855-A0T0SSG-A1A3000000 137N2570 – VACON NXP Air Cooled AC Drive, 200 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N2570 and type code NXP03855-A0T0SSG-A1A3000000+GSNT+SPXE is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC drive, frame FR09, IP54

VACON 

NXP03005-A5T0SSG-A1A20000E9 137N2553 – VACON NXP Air Cooled AC Drive, 160 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N2553 and type code NXP03005-A5T0SSG-A1A20000E9+QGLM+DPAP+GAAB is a 160 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR09 configuration...
VACON NXP Air Cooled AC drive, frame FR08, IP54

VACON 

NXP01405-A5H0SSV-A1AFB400E2 137N2536 – VACON NXP Air Cooled AC Drive, 75 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N2536 and type code NXP01405-A5H0SSV-A1AFB400E2+GSSE+DPAP+DLFR is a 75 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR08 configuration...