<
<
  • Search

VACON NXP Air Cooled 380-500 V

  • Home
  • Drives
  • VACON NXP
  • VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON® NXP is a high-performance air-cooled AC drive for demanding industrial applications such as cranes, winders, marine and process lines. It provides accurate open- and closed-loop motor control, five option-board slots for I/O, encoders and fieldbuses, and configurable application software.

View as:
Sidebar
VACON NXP Air Cooled AC drive, frame FR11, IP00

VACON 

NXP07305-A0N0NSB-A1AFB400EA 137N5661 – VACON NXP Air Cooled AC Drive, 400 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N5661 and type code NXP07305-A0N0NSB-A1AFB400EA is a 400 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR11 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR09, IP54

VACON 

NXP02615-A5H0SSG-A1A2000000 137N5672 – VACON NXP Air Cooled AC Drive, 132 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N5672 and type code NXP02615-A5H0SSG-A1A2000000+LS60+DPAP is a 132 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR09 configuration. It...
VACON NXP Air Cooled AC drive, frame FR10, IP00

VACON 

NXP05205-A0N0NSB-A1AFB400EA 137N5660 – VACON NXP Air Cooled AC Drive, 250 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N5660 and type code NXP05205-A0N0NSB-A1AFB400EA is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR09, IP21

VACON 

NXP03005-A2H0SSG-A1AFB400EA 137N5659 – VACON NXP Air Cooled AC Drive, 160 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N5659 and type code NXP03005-A2H0SSG-A1AFB400EA is a 160 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR09 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR05, IP54

VACON 

NXP00225-A5H1SSV-A1A2000000 137N5652 – VACON NXP Air Cooled AC Drive, 11 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N5652 and type code NXP00225-A5H1SSV-A1A2000000+QGLM+FL28+DPAP+DLSK is a 11 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR05...
VACON NXP Air Cooled AC drive, frame FR06, IP21

VACON 

NXP00455-A2T1SSV-A1A2AE0000 137N5641 – VACON NXP Air Cooled AC Drive, 22 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N5641 and type code NXP00455-A2T1SSV-A1A2AE0000+APFIFF20 is a 22 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It is...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00225-A2T1SSV-A1B1B1E600 137N5637 – VACON NXP Air Cooled AC Drive, 11 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N5637 and type code NXP00225-A2T1SSV-A1B1B1E600+DLES is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is...
VACON NXP Air Cooled AC drive, frame FR10, IP00

VACON 

NXP04605-A0N0SSB-A1A3000000 137N5598 – VACON NXP Air Cooled AC Drive, 250 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N5598 and type code NXP04605-A0N0SSB-A1A3000000+FL28+DLRO is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC drive, frame FR07, IP21

VACON 

NXP01055-A2H1SSV-A1AF000000 137N5603 – VACON NXP Air Cooled AC Drive, 55 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N5603 and type code NXP01055-A2H1SSV-A1AF000000+QGLM+ASITF030+DLIT is a 55 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Air Cooled AC drive, frame FR07, IP21

VACON 

NXP00725-A2H0SSV-A1AF000000 137N5613 – VACON NXP Air Cooled AC Drive, 37 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N5613 and type code NXP00725-A2H0SSV-A1AF000000+DPAP+DLIT is a 37 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00035-A2T2SSV-A1A2000000 137N5601 – VACON NXP Air Cooled AC Drive, 1.1 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N5601 and type code NXP00035-A2T2SSV-A1A2000000 is a 1.1 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 3...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00315-A2H1SSV-A1A200E300 137N5608 – VACON NXP Air Cooled AC Drive, 15 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N5608 and type code NXP00315-A2H1SSV-A1A200E300+DPAP+DLIT is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It...
  • Previous
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • Next