  • Search

VACON NXP

  • Home
  • Drives
  • VACON NXP

VACON NXP

VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC drive, frame FR12, IP00

VACON 

NXP09205-G0N1BSG-A1A200D2E9 137N4005 – VACON NXP Air Cooled AC Drive, 500 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N4005 and type code NXP09205-G0N1BSG-A1A200D2E9+FL26+DLCN is a 500 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR12 configuration. It...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00165-A2C1SSV-A1A2000000 137N3962 – VACON NXP Air Cooled AC Drive, 7.5 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N3962 and type code NXP00165-A2C1SSV-A1A2000000+DPAP+DLES is a 7.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It...
VACON NXP Air Cooled AC drive, frame FR08, IP21

VACON 

NXP01685-A2H0SSV-A1A2B4B200 137N3961 – VACON NXP Air Cooled AC Drive, 90 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N3961 and type code NXP01685-A2H0SSV-A1A2B4B200+FL24+DPAP+DLPL is a 90 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00315-A2H1SSV-A1AF00CP00 137N3960 – VACON NXP Air Cooled AC Drive, 15 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N3960 and type code NXP00315-A2H1SSV-A1AF00CP00+DPAP+DLFR+GNUL+GNCT+GNKC+GNUA+GNEA is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00315-A2H1SSV-A1A20000E2 137N3959 – VACON NXP Air Cooled AC Drive, 15 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N3959 and type code NXP00315-A2H1SSV-A1A20000E2+DPAP+DLIT is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It...
VACON NXP Air Cooled AC drive, frame FR11, IP00

VACON 

NXP04606-A0T1BSG-A1A20000E9 137N3950 – VACON NXP Air Cooled AC Drive, 450 kW, 525-690V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N3950 and type code NXP04606-A0T1BSG-A1A20000E9+ARFIFF02V141+GABV is a 450 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR11...
VACON NXP Air Cooled AC Drive 137N3946

VACON 

NXP09206-A0N0SSG-A1AFB4B5BH 137N3946 – VACON NXP Air Cooled AC Drive, 900 kW, 525-690V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N3946 and type code NXP09206-A0N0SSG-A1AFB4B5BH+FL21+DLFI is a 900 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR13 configuration. It...
VACON NXP Air Cooled AC drive, frame FR06, IP54

VACON 

NXP00385-A5T1SSV-A8A2000000 137N3720 – VACON NXP Air Cooled AC Drive, 18.5 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N3720 and type code NXP00385-A5T1SSV-A8A2000000+QGLM+FL21+DPAP+DLSE is a 18.5 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR06...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00125-A2T1SSV-A1A20000E9 137N3942 – VACON NXP Air Cooled AC Drive, 5.5 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N3942 and type code NXP00125-A2T1SSV-A1A20000E9+SWAY+APFIFF20+DPAP+DLES is a 5.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00315-A2T1SSV-A1A20000E9 137N3941 – VACON NXP Air Cooled AC Drive, 15 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N3941 and type code NXP00315-A2T1SSV-A1A20000E9+APFIFF20+DPAP+DLES is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05...
VACON NXP Air Cooled AC drive, frame FR06, IP21

VACON 

NXP00455-A2T1SSV-A1A3B40000 137N3890 – VACON NXP Air Cooled AC Drive, 22 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N3890 and type code NXP00455-A2T1SSV-A1A3B40000 is a 22 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It is rated 45...
VACON NXP Air Cooled AC Drive 137N3858

VACON 

NXP09206-G0N0SSG-A8A2B400E5 137N3858 – VACON NXP Air Cooled AC Drive, 900 kW, 525-690V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N3858 and type code NXP09206-G0N0SSG-A8A2B400E5+FL26+DLCN is a 900 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR13 configuration. It...