VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC drive, frame FR10, IP00

VACON 

NXP03855-A0T0TSO-A1A2000000 137N6126 – VACON NXP Air Cooled AC Drive, 200 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N6126 and type code NXP03855-A0T0TSO-A1A2000000+FL25+LS60+DLES is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration...
VACON NXP Air Cooled AC drive, frame FR10, IP00

VACON 

NXP04605-A0N0BSB-A1A2B4D2E2 137N6125 – VACON NXP Air Cooled AC Drive, 250 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N6125 and type code NXP04605-A0N0BSB-A1A2B4D2E2 is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR11, IP00

VACON 

NXP06505-A0N0BSB-A1A2B4D2E2 137N6124 – VACON NXP Air Cooled AC Drive, 355 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N6124 and type code NXP06505-A0N0BSB-A1A2B4D2E2 is a 355 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR11 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR06, IP54

VACON 

NXP00615-A5H1SSV-ANAF000000 137N6109 – VACON NXP Air Cooled AC Drive, 30 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N6109 and type code NXP00615-A5H1SSV-ANAF000000+QGLM+FL21 is a 30 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR06 configuration. It...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00035-A2H1SSV-A1B2000000 137N6107 – VACON NXP Air Cooled AC Drive, 1.1 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N6107 and type code NXP00035-A2H1SSV-A1B2000000 is a 1.1 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 3...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00125-A2H1SSV-A1AF0000E5 137N6101 – VACON NXP Air Cooled AC Drive, 5.5 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N6101 and type code NXP00125-A2H1SSV-A1AF0000E5+QGLM is a 5.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00325-A2H1SSV-A1A3BE00CI 137N6100 – VACON NXP Air Cooled AC Drive, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N6100 and type code NXP00325-A2H1SSV-A1A3BE00CI+BM50+FL21+DPAP+DLFI is a 32 A, three-phase 380-500 V supply, IP21 enclosure, frame FR05...
VACON NXP Air Cooled AC drive, frame FR06, IP54

VACON 

NXP00385-A5H1SSV-A1AF000000 137N6080 – VACON NXP Air Cooled AC Drive, 18.5 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N6080 and type code NXP00385-A5H1SSV-A1AF000000 is a 18.5 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR06 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR07, IP21

VACON 

NXP01055-A2T0SSV-A1A300B1E9 137N6093 – VACON NXP Air Cooled AC Drive, 55 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N6093 and type code NXP01055-A2T0SSV-A1A300B1E9 is a 55 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR04, IP54

VACON 

NXP00045-A5H1SSV-A1A3B1B4B5 137N6077 – VACON NXP Air Cooled AC Drive, 1.5 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N6077 and type code NXP00045-A5H1SSV-A1A3B1B4B5+FL24+DPAP+DLPL is a 1.5 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR04 configuration...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00165-A2T1SSV-A1A3A4B5E8 137N6064 – VACON NXP Air Cooled AC Drive, 7.5 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N6064 and type code NXP00165-A2T1SSV-A1A3A4B5E8 is a 7.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00125-A2H1SSV-A1A2B4E300 137N6063 – VACON NXP Air Cooled AC Drive, 5.5 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N6063 and type code NXP00125-A2H1SSV-A1A2B4E300 is a 5.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated...
  • Previous
  • 664
  • 665
  • 666
  • 667
  • 668
  • 669
  • 670
  • 671
  • 672
  • 673
  • 674
  • Next