VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC drive, frame FR08, IP21

VACON 

NXP01405-A2H0SSV-A1A2000000 137N8804 – VACON NXP Air Cooled AC Drive, 75 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N8804 and type code NXP01405-A2H0SSV-A1A2000000+DPAP+DLFR is a 75 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It...
VACON NXP Air Cooled AC drive, frame FR08, IP21

VACON 

NXP01685-A2H1SSV-ANAFA5CI00 137N8806 – VACON NXP Air Cooled AC Drive, 90 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N8806 and type code NXP01685-A2H1SSV-ANAFA5CI00+QGLM+FL23+DPAP+DLDE is a 90 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Air Cooled AC drive, frame FR11, IP00

VACON 

NXP06505-G0N0SSB-A8A2B4E200 137N8775 – VACON NXP Air Cooled AC Drive, 355 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N8775 and type code NXP06505-G0N0SSB-A8A2B4E200+FL26+DLCN is a 355 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR11 configuration. It...
VACON NXP Air Cooled AC drive, frame FR07, IP54

VACON 

NXP01055-A5H0SSV-A1AF000000 137N8785 – VACON NXP Air Cooled AC Drive, 55 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N8785 and type code NXP01055-A5H0SSV-A1AF000000+QGLM+FL23+DPAP+DLNL is a 55 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR07...
VACON NXP Air Cooled AC drive, frame FR10, IP00

VACON 

NXP03856-A0N0SSB-A1A2D7B5E2 137N8818 – VACON NXP Air Cooled AC Drive, 355 kW, 525-690V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N8818 and type code NXP03856-A0N0SSB-A1A2D7B5E2 is a 355 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00035-A2H1SSV-A1AF000000 137N8777 – VACON NXP Air Cooled AC Drive, 1.1 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N8777 and type code NXP00035-A2H1SSV-A1AF000000 is a 1.1 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 3...
VACON NXP Air Cooled AC drive, frame FR10, IP00

VACON 

NXP03856-A0N0SSB-A1A2D7E200 137N8817 – VACON NXP Air Cooled AC Drive, 355 kW, 525-690V, IP00

The VACON NXP Air Cooled AC Drive with order code 137N8817 and type code NXP03856-A0N0SSB-A1A2D7E200 is a 355 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR10, IP54

VACON 

NXP03855-A5L0OSB-A1A2B4E300 137N8781 – VACON NXP Air Cooled AC Drive, 200 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N8781 and type code NXP03855-A5L0OSB-A1A2B4E300 is a 200 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00315-A2T1SSV-A1A2000000 137N8797 – VACON NXP Air Cooled AC Drive, 15 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N8797 and type code NXP00315-A2T1SSV-A1A2000000+FL21+DLFI is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00045-A2T1SSV-A100B8B8E5 137N8733 – VACON NXP Air Cooled AC Drive, 1.5 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N8733 and type code NXP00045-A2T1SSV-A100B8B8E5+QGLM is a 1.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is...
VACON NXP Air Cooled AC drive, frame FR05, IP54

VACON 

NXP00225-F5H1SSV-A1B2A5D2E6 137N8721 – VACON NXP Air Cooled AC Drive, 11 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137N8721 and type code NXP00225-F5H1SSV-A1B2A5D2E6+FL24+DPAP+DLPL is a 11 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR05 configuration...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00045-A2T1SSV-A1000000E5 137N8730 – VACON NXP Air Cooled AC Drive, 1.5 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137N8730 and type code NXP00045-A2T1SSV-A1000000E5+QGLM is a 1.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is...