VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L2405

VACON 

NXA06506-A0T02PG-A1A2D700E9 137L2405 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 687 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L2405 and type code NXA06506-A0T02PG-A1A2D700E9+FL23+GRID+ARFIF106+DLDE is a 687 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L2126

VACON 

NXA13705-A0T02WG-A8B1000000 137L2126 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 839 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L2126 and type code NXA13705-A0T02WG-A8B1000000 is a 839 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L2120

VACON 

NXA16405-A0T02WG-A1A20000E9 137L2120 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1005 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L2120 and type code NXA16405-A0T02WG-A1A20000E9+ARFIFF05+GSNT+EMAR+LPC2+SPXE is a 1005 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L1912

VACON 

NXA02615-A0T02PG-A1B5BCE6E9 137L1912 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 160 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L1912 and type code NXA02615-A0T02PG-A1B5BCE6E9+ARFIFF30+GAIN is a 160 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L1911

VACON 

NXA08205-A0T02PG-A1B5BCE6E9 137L1911 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 502 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L1911 and type code NXA08205-A0T02PG-A1B5BCE6E9+ARFIFF30+EMAR is a 502 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L1910

VACON 

NXA07305-A0T02PG-A1B5BCE6E9 137L1910 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 448 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L1910 and type code NXA07305-A0T02PG-A1B5BCE6E9+ARFIFF30+EMAR is a 448 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137L1596

VACON 

NXB02086-A0T08WG-A8A20000E3 137L1596 – VACON NXP Liquid Cooled Common DC Bus Brake Chopper Unit, 346 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137L1596 and type code NXB02086-A0T08WG-A8A20000E3+SPXE is a 346 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L1908

VACON 

NXA02615-A0T02PG-A1B5BCE6E9 137L1908 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 160 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L1908 and type code NXA02615-A0T02PG-A1B5BCE6E9+ARFIFF30+EMAR is a 160 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L1909

VACON 

NXA03855-A0T02PG-A1B5BCE6E9 137L1909 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 236 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L1909 and type code NXA03855-A0T02PG-A1B5BCE6E9+ARFIFF30+EMAR is a 236 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L1594

VACON 

NXA17006-A0T02WG-A8A20000E3 137L1594 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1796 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L1594 and type code NXA17006-A0T02WG-A8A20000E3+SPXE is a 1796 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L1347

VACON 

NXA16405-A0T02WG-A8A2D700EA 137L1347 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1005 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L1347 and type code NXA16405-A0T02WG-A8A2D700EA is a 1005 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L1483

VACON 

NXA03855-A0T02WG-A1A2D7E6E9 137L1483 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 236 kW, 380-500V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L1483 and type code NXA03855-A0T02WG-A1A2D7E6E9+UGRD+ARFIF106+EMAR is a 236 kW, three-phase 380-500 V...