<
<
  • Search

VACON NXP

  • Home
  • Drives
  • VACON NXP

VACON NXP

VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137L9390

VACON 

NXB05028-A0T08WG-A1A20000E5 137L9390 – VACON NXP Liquid Cooled Common DC Bus Brake Chopper Unit, 838 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137L9390 and type code NXB05028-A0T08WG-A1A20000E5+GSNT+LPC2+SPXE is a 838 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9350

VACON 

NXP31006-A0T0IWG-A8A2B5E500 137L9350 – VACON NXP Liquid Cooled AC Drive, 525-690V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9350 and type code NXP31006-A0T0IWG-A8A2B5E500+GSNT+SPXE is a 3100 A, three-phase 525-690 V supply, IP00 enclosure, frame DH64...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L9351

VACON 

NXA17006-A0T02WG-A8B1D7E5D2 137L9351 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1796 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L9351 and type code NXA17006-A0T02WG-A8B1D7E5D2+GSNT+SPXE is a 1796 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137L9349

VACON 

NXB05028-A0T08WG-A8A2000000 137L9349 – VACON NXP Liquid Cooled Common DC Bus Brake Chopper Unit, 838 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137L9349 and type code NXB05028-A0T08WG-A8A2000000+GSNT+SPXE is a 838 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9173

VACON 

NXP01706-A0T0IWG-A1AFA5B8E9 137L9173 – VACON NXP Liquid Cooled AC Drive, 160 kW, 525-690V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9173 and type code NXP01706-A0T0IWG-A1AFA5B8E9+APFIFF09 is a 160 kW (250 HP), three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9171

VACON 

NXP03856-A0T0IWG-A1AFA5B8E9 137L9171 – VACON NXP Liquid Cooled AC Drive, 525-690V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9171 and type code NXP03856-A0T0IWG-A1AFA5B8E9+APFIFF09 is a 385 A, three-phase 525-690 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9170

VACON 

NXP05026-A0T0IWG-A1AFA5B8E9 137L9170 – VACON NXP Liquid Cooled AC Drive, 525-690V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9170 and type code NXP05026-A0T0IWG-A1AFA5B8E9+APFIFF09 is a 502 A, three-phase 525-690 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L9149

VACON 

NXA11806-A0T02WG-0000000000 137L9149 – VACON NXP Liquid Cooled Common DC Bus Active Front End Unit, 1247 kW, 525-690V, IP00

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L9149 and type code NXA11806-A0T02WG-0000000000+FL21+ARFIFF05+GSNT+GABV+LPC2+SPXE is a 1247 kW,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9111

VACON 

NXP03856-G0T0IWG-ANB10000E9 137L9111 – VACON NXP Liquid Cooled AC Drive, 525-690V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9111 and type code NXP03856-G0T0IWG-ANB10000E9+GSNT+SPXE is a 385 A, three-phase 525-690 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9112

VACON 

NXP05906-G0T0IWG-ANB1A500E9 137L9112 – VACON NXP Liquid Cooled AC Drive, 560 kW, 525-690V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9112 and type code NXP05906-G0T0IWG-ANB1A500E9+GSNT+SPXE is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9110

VACON 

NXP07506-G0T0IWG-ANB1D7E900 137L9110 – VACON NXP Liquid Cooled AC Drive, 700 kW, 525-690V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9110 and type code NXP07506-G0T0IWG-ANB1D7E900+GSNT+SPXE is a 700 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9103

VACON 

NXP17006-A0T0IWG-A8A2BC00E3 137L9103 – VACON NXP Liquid Cooled AC Drive, 525-690V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9103 and type code NXP17006-A0T0IWG-A8A2BC00E3+GSNT+SPXE is a 1700 A, three-phase 525-690 V supply, IP00 enclosure, frame CH64...
  • Previous
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • Next