VACON NXP

VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00225-A2H1SSV-A1A2B40000 137X1850 – VACON NXP Air Cooled AC Drive, 11 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137X1850 and type code NXP00225-A2H1SSV-A1A2B40000+QGLM+FL23+DLNL is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00035-A2H1SSV-A1A2A50000 137X1789 – VACON NXP Air Cooled AC Drive, 1.1 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137X1789 and type code NXP00035-A2H1SSV-A1A2A50000+QGLM+APITF033+DLDE is a 1.1 kW (1.5 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Air Cooled AC drive, frame FR04, IP54

VACON 

NXP00112-A5H1SSV-A1A30000E9 137X1727 – VACON NXP Air Cooled AC Drive, 2.2 kW, 230V, IP54

The VACON NXP Air Cooled AC Drive with order code 137X1727 and type code NXP00112-A5H1SSV-A1A30000E9 is a 2.2 kW (3 HP), three-phase 230 V supply, IP54 enclosure, frame FR04 configuration. It is...
VACON NXP Air Cooled AC drive, frame FR05, IP54

VACON 

NXP00252-A5H1SSV-A1A30000E9 137X1728 – VACON NXP Air Cooled AC Drive, 5.5 kW, 230V, IP54

The VACON NXP Air Cooled AC Drive with order code 137X1728 and type code NXP00252-A5H1SSV-A1A30000E9 is a 5.5 kW (7.5 HP), three-phase 230 V supply, IP54 enclosure, frame FR05 configuration. It is...
VACON NXP Air Cooled AC drive, frame FR08, IP21

VACON 

NXP02055-G2H0SSV-A1A20000E2 137X1719 – VACON NXP Air Cooled AC Drive, 110 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137X1719 and type code NXP02055-G2H0SSV-A1A20000E2+FL26+DPAP+DLCN is a 110 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration...
VACON NXP Air Cooled AC drive, frame FR11, IP00

VACON 

NXP06505-G0N0NSG-A1A200E200 137X1718 – VACON NXP Air Cooled AC Drive, 355 kW, 380-500V, IP00

The VACON NXP Air Cooled AC Drive with order code 137X1718 and type code NXP06505-G0N0NSG-A1A200E200 is a 355 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR11 configuration. It is rated...
VACON NXP Air Cooled AC drive, frame FR05, IP21

VACON 

NXP00225-A2H1SSV-A1AF0000E5 137X1717 – VACON NXP Air Cooled AC Drive, 11 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137X1717 and type code NXP00225-A2H1SSV-A1AF0000E5+FL24+DPAP+DLPL is a 11 kW (15 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR05...
VACON NXP Air Cooled AC drive, frame FR08, IP54

VACON 

NXP01685-A5H0SSV-A1A30000E9 137X1712 – VACON NXP Air Cooled AC Drive, 90 kW, 380-500V, IP54

The VACON NXP Air Cooled AC Drive with order code 137X1712 and type code NXP01685-A5H0SSV-A1A30000E9+QGLM+FL23+DPAP+DLDE is a 90 kW (125 HP), three-phase 380-500 V supply, IP54 enclosure, frame FR08...
VACON NXP Air Cooled AC drive, frame FR08, IP21

VACON 

NXP01405-A2H0SSV-A1A30000E9 137X1711 – VACON NXP Air Cooled AC Drive, 75 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137X1711 and type code NXP01405-A2H0SSV-A1A30000E9+QGLM+FL23+DPAP+DLDE is a 75 kW (100 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Air Cooled AC drive, frame FR04, IP21

VACON 

NXP00045-A2H1SSV-A1A30000E3 137X1716 – VACON NXP Air Cooled AC Drive, 1.5 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137X1716 and type code NXP00045-A2H1SSV-A1A30000E3+FL24+DPAP+DLPL is a 1.5 kW (2 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Air Cooled AC drive, frame FR07, IP21

VACON 

NXP00725-A2H1SSV-A1A30000E9 137X1710 – VACON NXP Air Cooled AC Drive, 37 kW, 380-500V, IP21

The VACON NXP Air Cooled AC Drive with order code 137X1710 and type code NXP00725-A2H1SSV-A1A30000E9+QGLM+FL23+DPAP+DLDE is a 37 kW (50 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Air Cooled AC drive, frame FR06, IP54

VACON 

NXP00186-A5T0SSV-A8A2000000 137X1709 – VACON NXP Air Cooled AC Drive, 15 kW, 525-690V, IP54

The VACON NXP Air Cooled AC Drive with order code 137X1709 and type code NXP00186-A5T0SSV-A8A2000000+DPAP+DLIT is a 15 kW (20 HP), three-phase 525-690 V supply, IP54 enclosure, frame FR06...