VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Grid Converter AC drive, frame FI09, IP00

VACON 

NXA01706-A0T02SG-A1A2D7B5E9 132L2238 – VACON NXP Grid Converter Active Front End Unit, 197 kW, 525-690V, IP00

The VACON NXP Grid Converter active front end unit with order code 132L2238 and type code NXA01706-A0T02SG-A1A2D7B5E9+MASG+ARFIFF03 is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Grid Converter AC drive, frame FI13, IP00

VACON 

NXA11505-A0T02SG-A1A2D7B5E9 132H7316 – VACON NXP Grid Converter Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Grid Converter active front end unit with order code 132H7316 and type code NXA11505-A0T02SG-A1A2D7B5E9+MASG+ARFIFF03+GAMA+LPC2 is a 773 kW, three-phase 380-500 V supply, IP00...
VACON NXP Grid Converter AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A2D7C6D6 132H7754 – VACON NXP Grid Converter Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Grid Converter active front end unit with order code 132H7754 and type code NXA03256-A0T02SG-A1A2D7C6D6+MASG+ARFIFF03 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Grid Converter AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A1A2D700E9 132H6422 – VACON NXP Grid Converter Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Grid Converter active front end unit with order code 132H6422 and type code NXA02615-A0T02SG-A1A2D700E9+MASG+ARFIFF03 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Grid Converter AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A3D700E9 132H1701 – VACON NXP Grid Converter Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Grid Converter active front end unit with order code 132H1701 and type code NXA04605-A0T02SG-A1A3D700E9+FL23+MASG+ARFIFF03+GSNT+GABV+SPXV is a 309 kW, three-phase 380-500 V supply, IP00...
VACON NXP Grid Converter AC drive, frame FI10, IP00

VACON 

NXA03256-G0T02SG-A1A2B50000 132H5359 – VACON NXP Grid Converter Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Grid Converter active front end unit with order code 132H5359 and type code NXA03256-G0T02SG-A1A2B50000+FL26+MASG+ARFIFF03+GSNT+DLRU+GNUL+EMAR+GNKC+GNUA+GNEA+LPC2+SPXC is a 377 kW,...
VACON NXP DC/DC Converter AC drive, frame FI12, IP00

VACON 

NXI06506-A0T0ISG-A1A2B5BHE9 137X2642 – VACON NXP DC/DC Converter Inverter Unit, 630 kW, 525-690V, IP00

The VACON NXP DC/DC Converter inverter unit with order code 137X2642 and type code NXI06506-A0T0ISG-A1A2B5BHE9+FL24+DCD3+ADFIF101+DLPL is a 630 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Grid Converter AC drive, frame FI13, IP00

VACON 

NXA10306-A0T02SG-A1A2D700EA 132H2610 – VACON NXP Grid Converter Active Front End Unit, 1194 kW, 525-690V, IP00

The VACON NXP Grid Converter active front end unit with order code 132H2610 and type code NXA10306-A0T02SG-A1A2D700EA+FL23+MASG+ARFIFF03 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Grid Converter AC drive, frame FI09, IP00

VACON 

NXA02615-A0T02SG-A8B1D7B1E9 132H6180 – VACON NXP Grid Converter Active Front End Unit, 175 kW, 380-500V, IP00

The VACON NXP Grid Converter active front end unit with order code 132H6180 and type code NXA02615-A0T02SG-A8B1D7B1E9+FL23+MASG+ARFIFF03+DNOT+GALR is a 175 kW, three-phase 380-500 V supply, IP00...
VACON NXP DC/DC Converter Inverter Unit 137X2123

VACON 

NXI00315-A2T0CSV-A8B5BH00EA 137X2123 – VACON NXP DC/DC Converter Inverter Unit, 15 kW, 380-500V, IP21

The VACON NXP DC/DC Converter inverter unit with order code 137X2123 and type code NXI00315-A2T0CSV-A8B5BH00EA+DCD3+ADFIF101 is a 15 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP DC/DC Converter AC drive, frame FR07, IP21

VACON 

NXI00875-A2T0CSV-A1B1000000 137X1876 – VACON NXP DC/DC Converter Inverter Unit, 45 kW, 380-500V, IP21

The VACON NXP DC/DC Converter inverter unit with order code 137X1876 and type code NXI00875-A2T0CSV-A1B1000000+DCD3+ADFIF101+LS60 is a 45 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP DC/DC Converter AC drive, frame FI09, IP00

VACON 

NXI01685-B0T0ISG-A100000000 137X1633 – VACON NXP DC/DC Converter Inverter Unit, 90 kW, 380-500V, IP00

The VACON NXP DC/DC Converter inverter unit with order code 137X1633 and type code NXI01685-B0T0ISG-A100000000+DCD3+ADFIF101 is a 90 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...