  • Search

VACON NXP

  • Home
  • Drives
  • VACON NXP

VACON NXP

VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A200B5E9 132N0131 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132N0131 and type code NXA03256-A0T02SG-A1A200B5E9+ARFIFF05 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB02615-B0T08SG-0000000000 132N0321 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132N0321 and type code NXB02615-B0T08SG-0000000000+FL21+DNOT is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB02615-B0T08SG-0000000000 132N0327 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132N0327 and type code NXB02615-B0T08SG-0000000000+FL21 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus AC drive, frame FR08, IP00

VACON 

NXB01006-G0T08SV-A1A2000000 132N0098 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132N0098 and type code NXB01006-G0T08SV-A1A2000000+FL26+DLCN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08...
VACON NXP Common DC Bus AC drive, frame FR08, IP21

VACON 

NXB01006-G2T08SV-A1A2000000 132N0096 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP21

The VACON NXP Common DC Bus brake chopper unit with order code 132N0096 and type code NXB01006-G2T08SV-A1A2000000+FL26+DLCN is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08...
VACON NXP Common DC Bus AC drive, frame FR08, IP00

VACON 

NXB01405-A0T08SV-A8A2000000 132L9935 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L9935 and type code NXB01405-A0T08SV-A8A2000000+FL26+DLCN is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR08...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A8A2B5E900 132L9931 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L9931 and type code NXA04605-A0T02SG-A8A2B5E900+FL26+DLCN is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB01256-G0T08SG-A1A2000000 132L9875 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L9875 and type code NXB01256-G0T08SG-A1A2000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXN06506-X0T0SSV-0000000000 132L9874 – VACON NXP Common DC Bus Rectifier Unit, 525-690V, IP00

The VACON NXP Common DC Bus rectifier unit with order code 132L9874 and type code NXN06506-X0T0SSV-0000000000+GNKC is a 650 A, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03856-A0T08SG-A1A3000000 132L9815 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L9815 and type code NXB03856-A0T08SG-A1A3000000+FL24 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXB03005-A0T08SG-A1B1A5B8E9 132L9382 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 380-500V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 132L9382 and type code NXB03005-A0T08SG-A1B1A5B8E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A2D700E9 132L9760 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 132L9760 and type code NXA03256-A0T02SG-A1A2D700E9+GRID+ARFIF106 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
  • Previous