VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA02616-G0T02SG-A8A2B500E9 137N5691 – VACON NXP Common DC Bus Active Front End Unit, 303 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N5691 and type code NXA02616-G0T02SG-A8A2B500E9+ARFIFF02V141+GACS is a 303 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A1A20000E9 137N5300 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N5300 and type code NXA04605-A0T02SG-A1A20000E9+ARFIFF05+GSSE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA03256-A0T02SG-A1A200D2CP 137N5274 – VACON NXP Common DC Bus Active Front End Unit, 377 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N5274 and type code NXA03256-A0T02SG-A1A200D2CP is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02055-A0T02SG-A8A200E200 137N5270 – VACON NXP Common DC Bus Active Front End Unit, 138 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N5270 and type code NXA02055-A0T02SG-A8A200E200+ARFIFF02V123+DLCN+GACS is a 138 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA02616-G0T02SG-A8A2B500E9 137N5062 – VACON NXP Common DC Bus Active Front End Unit, 303 kW, 525-690V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N5062 and type code NXA02616-G0T02SG-A8A2B500E9+ARFIFF02V141+GSNT+GACS+SPXE is a 303 kW, three-phase 525-690 V supply, IP00...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-A0T02SG-A1A20000E9 137N4609 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N4609 and type code NXA11505-A0T02SG-A1A20000E9+FL21+ARFIFF05+EMAR+LPC2+SPXE is a 773 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA02055-A0T02SG-A1A200CI00 137N4583 – VACON NXP Common DC Bus Active Front End Unit, 138 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N4583 and type code NXA02055-A0T02SG-A1A200CI00+FL23+ARFIFF02V141+DLDE is a 138 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXA04605-A0T02SG-A8A200CI00 137N4654 – VACON NXP Common DC Bus Active Front End Unit, 309 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N4654 and type code NXA04605-A0T02SG-A8A200CI00+FL26+ARFIF106+DLCN is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-A0T02SG-A1A20000E9 137N4473 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N4473 and type code NXA11505-A0T02SG-A1A20000E9+FL21+ARFIFF05+LPC2+SPXE is a 773 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI13, IP00

VACON 

NXA11505-A0T02SG-A1A20000E9 137N4460 – VACON NXP Common DC Bus Active Front End Unit, 773 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N4460 and type code NXA11505-A0T02SG-A1A20000E9+ARFIFF05+LPC2+SPXE is a 773 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI09, IP00

VACON 

NXA01685-G0T02SG-A1AFBH00E9 137N4401 – VACON NXP Common DC Bus Active Front End Unit, 114 kW, 380-500V, IP00

The VACON NXP Common DC Bus active front end unit with order code 137N4401 and type code NXA01685-G0T02SG-A1AFBH00E9+ARFIFF05+DNOT+LPC2 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus AC drive, frame FI10, IP00

VACON 

NXB03256-B0T08SO-0000000000 137N4047 – VACON NXP Common DC Bus Brake Chopper Unit, 2 kW, 525-690V, IP00

The VACON NXP Common DC Bus brake chopper unit with order code 137N4047 and type code NXB03256-B0T08SO-0000000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...
  • Previous
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • Next