<
<
  • Search

VACON NXP

  • Home
  • Drives
  • VACON NXP

VACON NXP

VACON® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACON® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Choose a range

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137U4137

VACON 

NXP03855-A0T0IPG-A1A2000000 137U4137 – VACON NXP Liquid Cooled AC Drive, 200 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U4137 and type code NXP03855-A0T0IPG-A1A2000000 is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH61...
VACON NXP Liquid Cooled AC drive, frame CH63, IP00

VACON 

NXP08205-A0T0SWG-A1A2D700E6 137U4017 – VACON NXP Liquid Cooled AC Drive, 450 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U4017 and type code NXP08205-A0T0SWG-A1A2D700E6+EMAR is a 450 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137U4117

VACON 

NXP03005-A0T0SWG-A1A20000E5 137U4117 – VACON NXP Liquid Cooled AC Drive, 160 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U4117 and type code NXP03005-A0T0SWG-A1A20000E5+APFIFF09+DLFR+EMAR is a 160 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137U4015

VACON 

NXP03855-A0T0IWG-A1A20000E6 137U4015 – VACON NXP Liquid Cooled AC Drive, 200 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U4015 and type code NXP03855-A0T0IWG-A1A20000E6+DCD3+ADFIF101+EMAR is a 200 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled AC drive, frame CH63, IP00

VACON 

NXP08205-A0N0SWG-A1A20000E2 137U3935 – VACON NXP Liquid Cooled AC Drive, 450 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U3935 and type code NXP08205-A0N0SWG-A1A20000E2+APFIF599+LPC2 is a 450 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled AC drive, frame CH63, IP00

VACON 

NXP09205-A0N0SWG-A1AF0000E9 137U3959 – VACON NXP Liquid Cooled AC Drive, 500 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U3959 and type code NXP09205-A0N0SWG-A1AF0000E9+FL23 is a 500 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled AC drive, frame CH05, IP00

VACON 

NXP01685-A0T0YWV-A1AF0000EA 137U3900 – VACON NXP Liquid Cooled AC Drive, 90 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U3900 and type code NXP01685-A0T0YWV-A1AF0000EA+DNOT is a 90 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH05...
VACON NXP Liquid Cooled AC drive, frame CH64, IP00

VACON 

NXP17006-A0T0IWG-A1A2000000 137U3958 – VACON NXP Liquid Cooled AC Drive, 525-690V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U3958 and type code NXP17006-A0T0IWG-A1A2000000+GALR is a 1700 A, three-phase 525-690 V supply, IP00 enclosure, frame CH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137U3899

VACON 

NXP05905-A0T0YWG-A1A2D7B4EA 137U3899 – VACON NXP Liquid Cooled AC Drive, 315 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U3899 and type code NXP05905-A0T0YWG-A1A2D7B4EA+MASG+ARFIFF03+DNOT+GALR is a 315 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137U3897

VACON 

NXP13705-A0T0YWG-A1AFA5B4EA 137U3897 – VACON NXP Liquid Cooled AC Drive, 700 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U3897 and type code NXP13705-A0T0YWG-A1AFA5B4EA+APFIFF09+DNOT+GALR is a 700 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled AC drive, frame CH05, IP00

VACON 

NXP01685-A0T0YWV-A1AF0000EA 137U3896 – VACON NXP Liquid Cooled AC Drive, 90 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U3896 and type code NXP01685-A0T0YWV-A1AF0000EA is a 90 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH05...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137U3895

VACON 

NXP05905-A0T0YWG-A1A2D7B4EA 137U3895 – VACON NXP Liquid Cooled AC Drive, 315 kW, 380-500V, IP00

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137U3895 and type code NXP05905-A0T0YWG-A1A2D7B4EA+MASG+ARFIFF03+GALR is a 315 kW, three-phase 380-500 V supply, IP00 enclosure,...
  • Previous
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • Next