<
<
  • Search

VACON NXP Liquid Cooled

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACONĀ® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

VACONĀ® NXP Liquid Cooled Enclosed Drive: technical overview

Extra protection for use in marine and heavy industries

VACON® NXP Liquid Cooled drives are integrated in a sturdy enclosure making them ideal for a wide range of industries with harsh operating conditions.

Liquid-cooled AC drives can be used in many combinations, from a single dedicated frequency converter to large-scale common DC bus systems. Packed with features, these fully standardized enclosed drives maximize the utilization of space while minimizing overall lifecycle costs.

Thanks to the high degree of protection (IP54), these drives can be installed almost anywhere in a plant or on a vessel. This eliminates the load on air-conditioning systems in electrical rooms reducing costs and installation time, and makes them ideal for retrofitting.

Servicing is fast and easy. Features such as safe torque off (STO) and safe stop 1 (SS1) improve safety, and conformal coated circuit boards enhance reliability.

 

Supply voltages and power range 

3 x 400-500 V...700-1100 kW

3 x 525-690 V...800-1550 kW

 

Features and benefits

  • Drive lifetime and reliability are enhanced due to sturdy cabinet protection
  • Floor space requirements and infrastructure needs are reduced as the compact design needs no air ducts
  • Investment savings as no large air-conditioning systems are needed due to minimal dissipation of heat loss to the air 
  • Fulfills all relevant international standards and global requirements including marine, safety, EMC and harmonics approvals
  • Virtually silent operation as no large cooling fans are needed

 

Applications

Compressors, wind turbines, extruders, pumps, fans, conveyors, crushers, thrusters, and propulsion, test-bench, crane, winch and power-conversion systems.

Sub Categories

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 525-690 V

VACON NXP Liquid Cooled 525-690 V

View as:
Sidebar
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9637

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1550 kW 525-690V IP00 - 137G9637

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9637 and type code NXP17006-A0T0UWG-A1AFB4BH00+FL21+DLSE is a 1550 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH74...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9365

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1250 kW 380-500V IP00 - 137G9365

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9365 and type code NXP23005-A0N0NWG-A1A20000E9+GALR is a 1250 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH74...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9281

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1500 A 525-690V IP00 - 137G9281

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9281 and type code NXP15006-A0T0IWG-A8AFBHBHE9+GSNT+GALR+LPC2+SPXE is a 1500 A, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G8896

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 110 kW 380-500V IP00 - 137G8896

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G8896 and type code NXP02055-A0N0SWV-A1A300D2E3+DLFI is a 110 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH05...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9423

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 385 A 525-690V IP00 - 137G9423

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9423 and type code NXP03856-A0T0IWG-A8B100CQE6 is a 385 A, three-phase 525-690 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G8684

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 850 kW 525-690V IP00 - 137G8684

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G8684 and type code NXP09206-A0T1TWG-A1A2B4B1E9+APFIFF09+DLFR+GABV is a 850 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9470

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 400 kW 525-690V IP00 - 137G9470

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9470 and type code NXP04606-B0T0SWG-A8B5D7E600+ARFIFF03 is a 400 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH72...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9452

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 380-500V IP00 - 137G9452

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9452 and type code NXP11505-A0T0IWG-A1A2D7BHE9+GRDC+ARFIF106+GADN+LPC2 is a 600 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9440

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 560 kW 380-500V IP00 - 137G9440

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9440 and type code NXP10305-A0T0IWG-A1AFB5D2E9+APFIF599+GAMA is a 560 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G8760

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 525-690V IP00 - 137G8760

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G8760 and type code NXP06506-A0T0IWG-A8A2BHB4E9+FL23+DLDE+GABV is a 600 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G8422

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 700 kW 525-690V IP00 - 137G8422

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G8422 and type code NXP07506-A0T0IWG-A1AFA5B8E9+APFIFF09+GSSE is a 700 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G8419

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 525-690V IP00 - 137G8419

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G8419 and type code NXP06506-A0T0IWG-A1AFA5B8E9+APFIFF09+GSSE is a 600 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
  • Previous
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • Next