VACONĀ® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

VACONĀ® NXP Liquid Cooled Enclosed Drive: technical overview

Extra protection for use in marine and heavy industries

VACON® NXP Liquid Cooled drives are integrated in a sturdy enclosure making them ideal for a wide range of industries with harsh operating conditions.

Liquid-cooled AC drives can be used in many combinations, from a single dedicated frequency converter to large-scale common DC bus systems. Packed with features, these fully standardized enclosed drives maximize the utilization of space while minimizing overall lifecycle costs.

Thanks to the high degree of protection (IP54), these drives can be installed almost anywhere in a plant or on a vessel. This eliminates the load on air-conditioning systems in electrical rooms reducing costs and installation time, and makes them ideal for retrofitting.

Servicing is fast and easy. Features such as safe torque off (STO) and safe stop 1 (SS1) improve safety, and conformal coated circuit boards enhance reliability.

 

Supply voltages and power range 

3 x 400-500 V...700-1100 kW

3 x 525-690 V...800-1550 kW

 

Features and benefits

  • Drive lifetime and reliability are enhanced due to sturdy cabinet protection
  • Floor space requirements and infrastructure needs are reduced as the compact design needs no air ducts
  • Investment savings as no large air-conditioning systems are needed due to minimal dissipation of heat loss to the air 
  • Fulfills all relevant international standards and global requirements including marine, safety, EMC and harmonics approvals
  • Virtually silent operation as no large cooling fans are needed

 

Applications

Compressors, wind turbines, extruders, pumps, fans, conveyors, crushers, thrusters, and propulsion, test-bench, crane, winch and power-conversion systems.

Sub Categories

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 525-690 V

VACON NXP Liquid Cooled 525-690 V

View as:
Sidebar
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H0381

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 525-690V IP00 - 137H0381

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H0381 and type code NXP05026-A0N0NWG-A9A2000000 is a 450 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH72...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H0205

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 160 kW 525-690V IP00 - 137H0205

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H0205 and type code NXP01706-A0T0IWG-0000000000 is a 160 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH61...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H0200

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 502 A 525-690V IP00 - 137H0200

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H0200 and type code NXP05026-A0T0IWG-0000000000 is a 502 A, three-phase 525-690 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H0186

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 200 kW 525-690V IP00 - 137H0186

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H0186 and type code NXP02086-A0T0IWG-0000000000 is a 200 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH61...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H0070

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 560 kW 525-690V IP00 - 137H0070

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H0070 and type code NXP05906-A0T0IWG-ANB8A5B1E9+APFIFF09+DLES is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H0062

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 700 kW 525-690V IP00 - 137H0062

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H0062 and type code NXP07506-A0T0IWG-ANB8A5B1E9+APFIFF09+DLES is a 700 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H0068

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1300 A 525-690V IP00 - 137H0068

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H0068 and type code NXP13006-A0T0IWG-ANB8A5B1E9+APFIFF09+DLES is a 1300 A, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137H0053

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1180 A 525-690V IP00 - 137H0053

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137H0053 and type code NXP11806-A0T0IWG-ANB8A5B1E9+APFIFF09+DLES is a 1180 A, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9726

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 525-690V IP00 - 137G9726

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9726 and type code NXP05026-A0N0SWG-A9A2000000 is a 450 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH72...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9683

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 250 kW 525-690V IP00 - 137G9683

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9683 and type code NXP02616-A0T0IWG-A1AFA5D2CI is a 250 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH61...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9644

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 520 A 380-500V IP00 - 137G9644

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9644 and type code NXP05205-A0T0IWG-A1A2BC00E9+EMAR is a 520 A, three-phase 380-500 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137G9451

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 380-500V IP00 - 137G9451

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137G9451 and type code NXP11505-A0T0IWG-A1A2D7BHE9+MASG+ARFIFF03+GADN+LPC2 is a 600 kW, three-phase 380-500 V supply, IP00...