VACONĀ® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

VACONĀ® NXP Liquid Cooled Enclosed Drive: technical overview

Extra protection for use in marine and heavy industries

VACON® NXP Liquid Cooled drives are integrated in a sturdy enclosure making them ideal for a wide range of industries with harsh operating conditions.

Liquid-cooled AC drives can be used in many combinations, from a single dedicated frequency converter to large-scale common DC bus systems. Packed with features, these fully standardized enclosed drives maximize the utilization of space while minimizing overall lifecycle costs.

Thanks to the high degree of protection (IP54), these drives can be installed almost anywhere in a plant or on a vessel. This eliminates the load on air-conditioning systems in electrical rooms reducing costs and installation time, and makes them ideal for retrofitting.

Servicing is fast and easy. Features such as safe torque off (STO) and safe stop 1 (SS1) improve safety, and conformal coated circuit boards enhance reliability.

 

Supply voltages and power range 

3 x 400-500 V...700-1100 kW

3 x 525-690 V...800-1550 kW

 

Features and benefits

  • Drive lifetime and reliability are enhanced due to sturdy cabinet protection
  • Floor space requirements and infrastructure needs are reduced as the compact design needs no air ducts
  • Investment savings as no large air-conditioning systems are needed due to minimal dissipation of heat loss to the air 
  • Fulfills all relevant international standards and global requirements including marine, safety, EMC and harmonics approvals
  • Virtually silent operation as no large cooling fans are needed

 

Applications

Compressors, wind turbines, extruders, pumps, fans, conveyors, crushers, thrusters, and propulsion, test-bench, crane, winch and power-conversion systems.

Sub Categories

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 525-690 V

VACON NXP Liquid Cooled 525-690 V

View as:
Sidebar
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9631

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 132 kW 380-500V IP00 - 137L9631

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9631 and type code NXP02615-A0N0SWV-A1A2000000+GSNT+SPXE is a 132 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH05...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9601

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1640 A 380-500V IP00 - 137L9601

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9601 and type code NXP16405-A0T0IWG-ANB1A500E3+GSNT+SPXE is a 1640 A, three-phase 380-500 V supply, IP00 enclosure, frame CH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9598

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 2340 A 525-690V IP00 - 137L9598

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9598 and type code NXP23406-B0T0IWG-ANA2A500E5+GSNT+SPXE is a 2340 A, three-phase 525-690 V supply, IP00 enclosure, frame DH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9599

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1700 A 525-690V IP00 - 137L9599

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9599 and type code NXP17006-B0T0IWG-ANA2D7B1E5+GSNT+SPXE is a 1700 A, three-phase 525-690 V supply, IP00 enclosure, frame CH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9596

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 385 A 525-690V IP00 - 137L9596

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9596 and type code NXP03856-B0T0IWG-ANA20000E5+GSNT+SPXE is a 385 A, three-phase 525-690 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9597

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 200 kW 525-690V IP00 - 137L9597

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9597 and type code NXP02086-B0T0IWG-ANA20000E5+GSNT+SPXE is a 200 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH61...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9594

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 2340 A 525-690V IP00 - 137L9594

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9594 and type code NXP23406-B0T0IWG-ANA2A5B1E5+GSNT+SPXE is a 2340 A, three-phase 525-690 V supply, IP00 enclosure, frame DH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9595

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1500 A 525-690V IP00 - 137L9595

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9595 and type code NXP15006-B0T0IWG-ANA2A5B1E5+GSNT+SPXE is a 1500 A, three-phase 525-690 V supply, IP00 enclosure, frame CH64...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9519

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 730 A 380-500V IP00 - 137L9519

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9519 and type code NXP07305-A0T0IPG-A1A2000000 is a 730 A, three-phase 380-500 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9389

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 3100 A 525-690V IP00 - 137L9389

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9389 and type code NXP31006-A0T0IWG-A8B1A5B1E5+ARFIFF30+GSNT+LPC2+SPXE is a 3100 A, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L9508

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 600 kW 380-500V IP00 - 137L9508

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L9508 and type code NXP11505-A0T0IWG-A1A20000E9+FL23+DCD3+ADFIF101 is a 600 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137L8160

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1700 A 525-690V IP00 - 137L8160

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137L8160 and type code NXP17006-A0T0IWG-ANAF00B5EA+DCG2+ADFIF102 is a 1700 A, three-phase 525-690 V supply, IP00 enclosure, frame...