<
<
  • Search

VACON NXP Liquid Cooled

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACONĀ® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

VACONĀ® NXP Liquid Cooled Enclosed Drive: technical overview

Extra protection for use in marine and heavy industries

VACON® NXP Liquid Cooled drives are integrated in a sturdy enclosure making them ideal for a wide range of industries with harsh operating conditions.

Liquid-cooled AC drives can be used in many combinations, from a single dedicated frequency converter to large-scale common DC bus systems. Packed with features, these fully standardized enclosed drives maximize the utilization of space while minimizing overall lifecycle costs.

Thanks to the high degree of protection (IP54), these drives can be installed almost anywhere in a plant or on a vessel. This eliminates the load on air-conditioning systems in electrical rooms reducing costs and installation time, and makes them ideal for retrofitting.

Servicing is fast and easy. Features such as safe torque off (STO) and safe stop 1 (SS1) improve safety, and conformal coated circuit boards enhance reliability.

 

Supply voltages and power range 

3 x 400-500 V...700-1100 kW

3 x 525-690 V...800-1550 kW

 

Features and benefits

  • Drive lifetime and reliability are enhanced due to sturdy cabinet protection
  • Floor space requirements and infrastructure needs are reduced as the compact design needs no air ducts
  • Investment savings as no large air-conditioning systems are needed due to minimal dissipation of heat loss to the air 
  • Fulfills all relevant international standards and global requirements including marine, safety, EMC and harmonics approvals
  • Virtually silent operation as no large cooling fans are needed

 

Applications

Compressors, wind turbines, extruders, pumps, fans, conveyors, crushers, thrusters, and propulsion, test-bench, crane, winch and power-conversion systems.

Sub Categories

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 525-690 V

VACON NXP Liquid Cooled 525-690 V

View as:
Sidebar
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2630

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 500 kW 380-500V IP00 - 137N2630

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2630 and type code NXP09205-A0T0IWG-A1AF00BHE6+APFIFF09+GABV is a 500 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2628

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 1370 A 380-500V IP00 - 137N2628

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2628 and type code NXP13705-A0T0IWG-A1AFBCBHE6+APFIFF09+GABV is a 1370 A, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2619

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 90 kW 380-500V IP00 - 137N2619

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2619 and type code NXP01685-A0T0SWG-A1AF0000E7+APFIFF09 is a 90 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH05...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2618

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 520 A 380-500V IP00 - 137N2618

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2618 and type code NXP05205-A0T0IWG-A1A2D700E6+MASG+ARFIFF03 is a 520 A, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2617

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 355 kW 380-500V IP00 - 137N2617

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2617 and type code NXP06505-A0T0SWG-A1AF0000E7+APFIFF09 is a 355 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH72...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2615

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 137N2615

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2615 and type code NXP08205-A0T0SWG-A1AFBCD2E7+APFIFF09 is a 450 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2614

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 160 kW 380-500V IP00 - 137N2614

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2614 and type code NXP03005-A0T0SWG-A1A2D700E6+MASG+ARFIFF03 is a 160 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2585

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 500 kW 380-500V IP00 - 137N2585

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2585 and type code NXP09205-A0T0SWG-A1AFBCBHE9+APFIFF09 is a 500 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2599

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 137N2599

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2599 and type code NXP08205-A0T0NWG-A1AF0000E6+APFIFF09 is a 450 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2584

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 460 A 380-500V IP00 - 137N2584

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2584 and type code NXP04605-A0T0IWG-A1A2D700E9+MASG+ARFIFF03 is a 460 A, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2454

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 560 kW 380-500V IP00 - 137N2454

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2454 and type code NXP10305-A0T0SWG-A1A2D700E6+MASG+ARFIFF03+GAIN is a 560 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2453

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 500 kW 380-500V IP00 - 137N2453

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2453 and type code NXP09205-A0T0SWG-A1AF00BHE6+APFIFF09+GAIN is a 500 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
  • Previous
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • Next