<
<
  • Search

VACON NXP Liquid Cooled

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACONĀ® NXP Liquid Cooled drives transfer losses directly into a liquid circuit. They suit installations where space is limited, air quality is critical or heat must be removed efficiently, such as marine, offshore, mining and heavy industry.

VACONĀ® NXP Liquid Cooled Enclosed Drive: technical overview

Extra protection for use in marine and heavy industries

VACON® NXP Liquid Cooled drives are integrated in a sturdy enclosure making them ideal for a wide range of industries with harsh operating conditions.

Liquid-cooled AC drives can be used in many combinations, from a single dedicated frequency converter to large-scale common DC bus systems. Packed with features, these fully standardized enclosed drives maximize the utilization of space while minimizing overall lifecycle costs.

Thanks to the high degree of protection (IP54), these drives can be installed almost anywhere in a plant or on a vessel. This eliminates the load on air-conditioning systems in electrical rooms reducing costs and installation time, and makes them ideal for retrofitting.

Servicing is fast and easy. Features such as safe torque off (STO) and safe stop 1 (SS1) improve safety, and conformal coated circuit boards enhance reliability.

 

Supply voltages and power range 

3 x 400-500 V...700-1100 kW

3 x 525-690 V...800-1550 kW

 

Features and benefits

  • Drive lifetime and reliability are enhanced due to sturdy cabinet protection
  • Floor space requirements and infrastructure needs are reduced as the compact design needs no air ducts
  • Investment savings as no large air-conditioning systems are needed due to minimal dissipation of heat loss to the air 
  • Fulfills all relevant international standards and global requirements including marine, safety, EMC and harmonics approvals
  • Virtually silent operation as no large cooling fans are needed

 

Applications

Compressors, wind turbines, extruders, pumps, fans, conveyors, crushers, thrusters, and propulsion, test-bench, crane, winch and power-conversion systems.

Sub Categories

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 380-500 V

VACON NXP Liquid Cooled 525-690 V

VACON NXP Liquid Cooled 525-690 V

View as:
Sidebar
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N3001

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 700 kW 525-690V IP00 - 137N3001

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N3001 and type code NXP07506-A0T0IPG-ANB1BCB1D2+ARFIFF30+GANK is a 700 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2979

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 250 kW 380-500V IP00 - 137N2979

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2979 and type code NXP05205-A0N0NWG-A1A2B4B8B8+FL21+DLFI is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH72...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2857

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 250 kW 380-500V IP00 - 137N2857

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2857 and type code NXP05205-A0N0SWG-A1A2000000+DLES is a 250 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH72...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2838

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 315 kW 380-500V IP00 - 137N2838

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2838 and type code NXP05905-A0N0YWG-A8AFB100E9+APFIFF09 is a 315 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH72...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2740

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 400 kW 525-690V IP00 - 137N2740

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2740 and type code NXP04606-G0T0NWG-A1A20000CP is a 400 kW, three-phase 525-690 V supply, IP00 enclosure, frame CH72...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2690

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 460 A 380-500V IP00 - 137N2690

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2690 and type code NXP04605-A0T0IWG-A1A2A500E7+ARFIFF30 is a 460 A, three-phase 380-500 V supply, IP00 enclosure, frame CH62...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2670

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 315 kW 380-500V IP00 - 137N2670

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2670 and type code NXP05905-A0T1SWG-A1AFA5BHE7+FL23+APFIFF09 is a 315 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2673

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 315 kW 380-500V IP00 - 137N2673

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2673 and type code NXP05905-A0T0SWG-A1A2D700E7+MASG+ARFIFF03 is a 315 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2668

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 200 kW 380-500V IP00 - 137N2668

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2668 and type code NXP03855-A0T0SWG-A1A2D700E7+MASG+ARFIFF03 is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2665

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 200 kW 380-500V IP00 - 137N2665

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2665 and type code NXP03855-A0T0SWG-A1AFA5BHE7+APFIFF09 is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH61...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2657

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 90 kW 380-500V IP00 - 137N2657

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2657 and type code NXP01685-A0T0SWG-A1AF0000E6+APFIFF09 is a 90 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH05...
VACON NXP Liquid Cooled Liquid-Cooled AC Drive 137N2658

VACON 

VACON NXP Liquid Cooled Liquid-Cooled AC Drive 450 kW 380-500V IP00 - 137N2658

The VACON NXP Liquid Cooled liquid-cooled ac drive with order code 137N2658 and type code NXP08205-A0T0SWG-A1AFBCD2E6+APFIFF09 is a 450 kW, three-phase 380-500 V supply, IP00 enclosure, frame CH63...
  • Previous
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • Next