VACONĀ® NXP Liquid Cooled Common DC Bus modules combine liquid cooling with a shared DC bus for compact, high-power multi-drive systems up to several megawatts in marine, offshore and process industry.

VACONĀ® NXP Liquid Cooled Common DC Bus: technical overview

Easy integration – ultimate flexibility

With one of the best power/size ratios, VACON® NXP Liquid Cooled drives are ideal for applications where space is at a premium or air cooling is difficult. Heavy industries with harsh operating conditions, such as in marine, offshore and mining environments benefit from the drive’s compact design and robust reliability.

The VACON® NXP range of common Liquid Cooled DC bus drive products includes front-end units, inverters and brake-chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

As a high degree of protection (IP54 or higher) can easily be achieved with these drives, they can be installed almost anywhere in a plant or on a vessel. This eliminates the load on air-conditioning systems in electrical rooms reducing costs and installation time, and makes them ideal for retrofitting.

 

Supply voltages and power range 

3 x 400-500 V...7.5-4100 kW
3 x 525-690 V...110-5300 kW

 

Features and benefits

  • Reduced energy costs as regenerative filter feeds excess braking energy back into network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications 

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Liquid Cooled Common DC Bus 380-500 V

VACON NXP Liquid Cooled Common DC Bus 380-500 V

VACON NXP Liquid Cooled Common DC Bus 525-690 V

VACON NXP Liquid Cooled Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1459

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1744 kW 525-690V IP00 - 132H1459

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1459 and type code NXA15006-A0T02WG-A1A3D7D2EC+MASG+ARFIFF03+GADN is a 1744 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1397

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 535 kW 525-690V IP00 - 132H1397

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1397 and type code NXA04606-A0T02WG-A8B1D7D6CI+MASG+ARFIFF03 is a 535 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1395

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 378 kW 525-690V IP00 - 132H1395

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1395 and type code NXA03256-A0T02WG-A8B1D7D6CI+MASG+ARFIFF03 is a 378 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1392

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 686 kW 525-690V IP00 - 132H1392

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1392 and type code NXA05906-A0T02WG-A8B500D6CI is a 686 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1106

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1860 kW 380-500V IP00 - 132H1106

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1106 and type code NXA23005-A0T02WG-0000000000+GSSE+GADN is a 1860 kW, three-phase 380-500 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1394

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 584 kW 525-690V IP00 - 132H1394

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1394 and type code NXA05026-A0T02WG-A8B500D6CI is a 584 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1115

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 132H1115

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1115 and type code NXA20605-A0T02WG-A8B500D2EC+MASG+ARFIFF03+GALR is a 1262 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1105

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 132H1105

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1105 and type code NXA20605-A0T02WG-A8B500D2EC+MASG+ARFIFF03+GADN is a 1262 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H1079

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1005 kW 380-500V IP00 - 132H1079

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H1079 and type code NXA16405-A0T02WG-A8B5D7D2EC+GAAB is a 1005 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H0931

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 660 kW 380-500V IP00 - 132H0931

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H0931 and type code NXA08205-A0T02WG-A1A2B500E9+LS60 is a 660 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H0854

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 113 kW 380-500V IP00 - 132H0854

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H0854 and type code NXA01685-A0T02WG-A8AFD7B5E9+MASG+ARFIFF03+GAIN is a 113 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 132H0438

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 378 kW 525-690V IP00 - 132H0438

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 132H0438 and type code NXA03256-A0T02WG-A1A2D700CI+MASG+ARFIFF03 is a 378 kW, three-phase 525-690 V...
  • Previous
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • Next