  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 132H2872

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132H2872

The VACON NXP Common DC Bus active front end unit with order code 132H2872 and type code NXA04605-A0T02SG-A1A2B50000+GSNT+DLFR+SPXC is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 132H2871

VACON 

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 132H2871

The VACON NXP Common DC Bus active front end unit with order code 132H2871 and type code NXA01706-A0T02SG-A1A2B50000+GSNT+SPXC is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132H2674

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132H2674

The VACON NXP Common DC Bus active front end unit with order code 132H2674 and type code NXA04605-A0T02SG-A1B1A5B8E9+ARFIFF05 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132H2611

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 132H2611

The VACON NXP Common DC Bus active front end unit with order code 132H2611 and type code NXA10306-A0T02SG-A1A20000EA+FL23+ARFIFF03 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 132H2499

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132H2499

The VACON NXP Common DC Bus brake chopper unit with order code 132H2499 and type code NXB00385-A2T08SV-A8A20000CI is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 132H2434

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132H2434

The VACON NXP Common DC Bus active front end unit with order code 132H2434 and type code NXA04605-A0T02SG-A1A2D700EA+GRID+ARFIF106 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 132H2476

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 132H2476

The VACON NXP Common DC Bus active front end unit with order code 132H2476 and type code NXA01685-A0T02SG-A8A2B5D2E9+FL25+LS60 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132H2260

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132H2260

The VACON NXP Common DC Bus active front end unit with order code 132H2260 and type code NXA03855-A0T02SG-A1A2D700EA+GRID+ARFIF106 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 132H2358

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132H2358

The VACON NXP Common DC Bus brake chopper unit with order code 132H2358 and type code NXB05205-A0T08SG-A1A20000E9+FL23+DLNL is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132H2084

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132H2084

The VACON NXP Common DC Bus brake chopper unit with order code 132H2084 and type code NXB04166-G0T08SG-A1B10000CP+FL26+DLCN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132H2135

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132H2135

The VACON NXP Common DC Bus brake chopper unit with order code 132H2135 and type code NXB04166-G0T08SG-A1B50000CP+FL26+DLCN+GACS is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132H1913

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 132H1913

The VACON NXP Common DC Bus active front end unit with order code 132H1913 and type code NXA10306-A0T02SG-A1A2B5E9EA is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
  • Previous
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • Next