<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 132H4979

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132H4979

The VACON NXP Common DC Bus active front end unit with order code 132H4979 and type code NXA03855-A0T02SG-A8A2B500E3 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132H5628

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132H5628

The VACON NXP Common DC Bus brake chopper unit with order code 132H5628 and type code NXB00315-A2T08SV-A1A20000E6+QGLM+FL21 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Active Front End Unit 132H5085

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132H5085

The VACON NXP Common DC Bus active front end unit with order code 132H5085 and type code NXA03855-A0T02SG-A8A2B50000 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132H4977

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132H4977

The VACON NXP Common DC Bus brake chopper unit with order code 132H4977 and type code NXB01055-A2T08SV-A8A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 132H5401

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 132H5401

The VACON NXP Common DC Bus active front end unit with order code 132H5401 and type code NXA03256-G0T02SG-A1A2B50000+FL26+ARFIFF05+GSNT+DLRU+GNUL+EMAR+GNKC+GNUA+GNEA+LPC2+SPXC is a 377 kW,...
VACON NXP Common DC Bus Active Front End Unit 132H5612

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132H5612

The VACON NXP Common DC Bus active front end unit with order code 132H5612 and type code NXA04605-A0T02SG-A1A2B50000+FL21+ARFIFF05+GSNT+GNUL+GNKC+LPC2+SPXV is a 309 kW, three-phase 380-500 V supply,...
VACON NXP Common DC Bus Active Front End Unit 132H5689

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 132H5689

The VACON NXP Common DC Bus active front end unit with order code 132H5689 and type code NXA02615-A0T02SG-A1A2B50000+FL24+GSNT+DLCZ+LPC2+SPXV is a 175 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 132H4991

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132H4991

The VACON NXP Common DC Bus active front end unit with order code 132H4991 and type code NXA04605-A0T02SG-A1A2B5E9EA+FL23+ARFIFF05+DLDE+LPC2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 132H4960

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132H4960

The VACON NXP Common DC Bus brake chopper unit with order code 132H4960 and type code NXB03256-G0T08SG-A8A20000E3+GNUL is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132H4974

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132H4974

The VACON NXP Common DC Bus active front end unit with order code 132H4974 and type code NXA04605-A0T02SG-A8A2B500E3 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132H4651

VACON 

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 132H4651

The VACON NXP Common DC Bus active front end unit with order code 132H4651 and type code NXA01706-A0T02SG-A1A2000000+DLCN is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132H3968

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 132H3968

The VACON NXP Common DC Bus active front end unit with order code 132H3968 and type code NXA10306-A0T02SG-A1A2B50000+GSNT+GALR+SPXV is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
  • Previous
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • Next