<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 132X6933

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 132X6933

The VACON NXP Common DC Bus active front end unit with order code 132X6933 and type code NXA01685-G0T02SG-A1A2B50000 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 132X6923

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132X6923

The VACON NXP Common DC Bus brake chopper unit with order code 132X6923 and type code NXB04605-G0T08SG-A1A2000000+FL26+DLCN+GACS is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132X6921

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 132X6921

The VACON NXP Common DC Bus active front end unit with order code 132X6921 and type code NXA02615-G0T02SG-A1A2D7BEE9+FL26+DLCN+GACS is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 132X6849

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 132X6849

The VACON NXP Common DC Bus active front end unit with order code 132X6849 and type code NXA13005-A0T02SG-A1A2B500E9+GSNT+EMAR+LPC2+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 132X6797

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132X6797

The VACON NXP Common DC Bus active front end unit with order code 132X6797 and type code NXA03855-A0T02SG-A1A2D700E6+UGRD+ARFIF106 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 132X6844

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132X6844

The VACON NXP Common DC Bus active front end unit with order code 132X6844 and type code NXA04605-A0T02SG-A1A2D7B5E9+ARFIFF05+GSNT+DLFR+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 132X6765

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 132X6765

The VACON NXP Common DC Bus active front end unit with order code 132X6765 and type code NXA13005-A0T02SG-A8A2B1D2EA is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 132X6764

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132X6764

The VACON NXP Common DC Bus active front end unit with order code 132X6764 and type code NXA04605-A0T02SG-A8A2B1D2EA is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132X6692

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 132X6692

The VACON NXP Common DC Bus active front end unit with order code 132X6692 and type code NXA10306-A0T02SG-A1A2B1D6E5 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 132X6679

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132X6679

The VACON NXP Common DC Bus active front end unit with order code 132X6679 and type code NXA03855-G0T02SG-A1A2B50000+ARFIF106 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132X6678

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 132X6678

The VACON NXP Common DC Bus active front end unit with order code 132X6678 and type code NXA01685-G0T02SG-A1A2B50000+ARFIF106 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 132X6561

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132X6561

The VACON NXP Common DC Bus brake chopper unit with order code 132X6561 and type code NXB04605-A0T08SG-A1A30000E6+FL24 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
  • Previous
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • Next