VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 132X7795

VACON 

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 132X7795

The VACON NXP Common DC Bus active front end unit with order code 132X7795 and type code NXA01706-A0T02SG-A1A2000000+FL23+DLNL is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132X7815

VACON 

VACON NXP Common DC Bus Active Front End Unit 1067 kW 525-690V IP00 - 132X7815

The VACON NXP Common DC Bus active front end unit with order code 132X7815 and type code NXA09206-A0T02SG-A1A2D700CP+GRDC+ARFIF106 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 132X7745

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 132X7745

The VACON NXP Common DC Bus active front end unit with order code 132X7745 and type code NXA02615-A0T02SG-A1A2D7BHE9+GRID+ARFIF106 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 132X7662

VACON 

VACON NXP Common DC Bus Active Front End Unit 1067 kW 525-690V IP00 - 132X7662

The VACON NXP Common DC Bus active front end unit with order code 132X7662 and type code NXA09206-A0T02SG-A1A2D700E9+GRDC+ARFIF106 is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 132X7425

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132X7425

The VACON NXP Common DC Bus brake chopper unit with order code 132X7425 and type code NXB03855-A0T08SG-A8A20000E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132X7424

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132X7424

The VACON NXP Common DC Bus brake chopper unit with order code 132X7424 and type code NXB03855-A0T08SG-A8A20000E9+GACS is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 132X7333

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132X7333

The VACON NXP Common DC Bus brake chopper unit with order code 132X7333 and type code NXB00875-A2T08SV-A1A2000000+QGLM+FL23+DLDE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Brake Chopper Unit 132X7306

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132X7306

The VACON NXP Common DC Bus brake chopper unit with order code 132X7306 and type code NXB01405-A2T08SV-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 132X7157

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 132X7157

The VACON NXP Common DC Bus brake chopper unit with order code 132X7157 and type code NXB01706-A0T08SG-A1A2000000+EMAR is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 132X7127

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132X7127

The VACON NXP Common DC Bus brake chopper unit with order code 132X7127 and type code NXB02615-A0T08SG-A1A20000E9+FL23 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132X7033

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132X7033

The VACON NXP Common DC Bus active front end unit with order code 132X7033 and type code NXA04605-A0T02SG-A8A2B50000+ARFIFF05+GSNT+GABV+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 132X7031

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 132X7031

The VACON NXP Common DC Bus active front end unit with order code 132X7031 and type code NXA13005-A0T02SG-A8A2B50000+ARFIFF05+GSNT+GABV+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...