  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 132X9130

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132X9130

The VACON NXP Common DC Bus active front end unit with order code 132X9130 and type code NXA04605-A0T02SG-A1A20000E2+FL26+DLCN is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132X9129

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 132X9129

The VACON NXP Common DC Bus active front end unit with order code 132X9129 and type code NXA02615-A0T02SG-A1A20000E2+FL26+DLCN is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132X8929

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132X8929

The VACON NXP Common DC Bus active front end unit with order code 132X8929 and type code NXA04605-A0T02SG-A1A2D700E9+ARFIFF05+DLFR is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 132X9029

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132X9029

The VACON NXP Common DC Bus brake chopper unit with order code 132X9029 and type code NXB02615-B0T08SG-A1A2000000+FL21+DNOT is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 132X8872

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 132X8872

The VACON NXP Common DC Bus active front end unit with order code 132X8872 and type code NXA13005-A0T02SG-A1B8B500E9 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 132X8760

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 132X8760

The VACON NXP Common DC Bus brake chopper unit with order code 132X8760 and type code NXB00875-A2T08SV-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 132X8715

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 132X8715

The VACON NXP Common DC Bus active front end unit with order code 132X8715 and type code NXA02615-A0T02SG-A8A2B1D2EA is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 132X8684

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 132X8684

The VACON NXP Common DC Bus brake chopper unit with order code 132X8684 and type code NXB02615-B0T08SG-A1A2000000+FL21+GSNT+DNOT+LPC2+SPXE is a 2 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 132X8646

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 132X8646

The VACON NXP Common DC Bus active front end unit with order code 132X8646 and type code NXA11505-A0T02SG-A1A2B50000+ARFIFF05 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 132X8609

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 132X8609

The VACON NXP Common DC Bus active front end unit with order code 132X8609 and type code NXA03855-G0T02SG-A1A2D7B5CI is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132X8598

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 132X8598

The VACON NXP Common DC Bus active front end unit with order code 132X8598 and type code NXA04605-G0T02SG-A1A2D7B5CI is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 132X8408

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 132X8408

The VACON NXP Common DC Bus active front end unit with order code 132X8408 and type code NXA03256-A0T02SG-A1A2000000+FL21+GRID+ARFIF106+GSNT+LPC2+SPXE is a 377 kW, three-phase 525-690 V supply, IP00...