<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 136H7582

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136H7582

The VACON NXP Common DC Bus active front end unit with order code 136H7582 and type code NXA13005-B0T02SG-A1A2000000+ARFIFF02V123+DLES is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 136H8706

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 136H8706

The VACON NXP Common DC Bus active front end unit with order code 136H8706 and type code NXA02615-G0T02SG-A1A2000000+FL26+DLCN is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136H7250

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136H7250

The VACON NXP Common DC Bus active front end unit with order code 136H7250 and type code NXA10306-A0T02SG-A1A2B50000 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136H7045

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 136H7045

The VACON NXP Common DC Bus active front end unit with order code 136H7045 and type code NXA02615-A0T02SG-A1A200B5D2+FL23+DLDE is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 136H5984

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136H5984

The VACON NXP Common DC Bus brake chopper unit with order code 136H5984 and type code NXB04605-A0T08SG-A1A2B50000+FL23 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 136H5981

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136H5981

The VACON NXP Common DC Bus active front end unit with order code 136H5981 and type code NXA13005-A0T02SG-A1A2B50000+FL23 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Rectifier Unit 136H5695

VACON 

VACON NXP Common DC Bus Rectifier Unit 650 A 525-690V IP00 - 136H5695

The VACON NXP Common DC Bus rectifier unit with order code 136H5695 and type code NXN06506-X0T0NSV-0000000000 is a 650 A, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration. It is...
VACON NXP Common DC Bus Active Front End Unit 136H4755

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136H4755

The VACON NXP Common DC Bus active front end unit with order code 136H4755 and type code NXA13005-A0T02SG-A1A20000CI is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136H4517

VACON 

VACON NXP Common DC Bus Active Front End Unit 138 kW 380-500V IP00 - 136H4517

The VACON NXP Common DC Bus active front end unit with order code 136H4517 and type code NXA02055-A0T02SG-A1A2000000 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136H4382

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 136H4382

The VACON NXP Common DC Bus active front end unit with order code 136H4382 and type code NXA04605-A0T02SG-A1A20000E9+DLES is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 136H4402

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136H4402

The VACON NXP Common DC Bus brake chopper unit with order code 136H4402 and type code NXB01685-A0T08SG-A1A20000E9+DLES is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136H4363

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 136H4363

The VACON NXP Common DC Bus active front end unit with order code 136H4363 and type code NXA04605-A0T02SG-A1A200B5E9+DLES is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
  • Previous
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • Next