  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 136L2889

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136L2889

The VACON NXP Common DC Bus brake chopper unit with order code 136L2889 and type code NXB02615-A0T08SG-A1A2B800E9+DLES is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136L3012

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 136L3012

The VACON NXP Common DC Bus active front end unit with order code 136L3012 and type code NXA02615-A0T02SG-A1A2D700CI+GRID+ARFIF106 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 136L2850

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 75 kW 380-500V IP21 - 136L2850

The VACON NXP Common DC Bus brake chopper unit with order code 136L2850 and type code NXB01405-A2T08SV-A1A200D6E9+QGLM is a 75 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Common DC Bus Active Front End Unit 136L2706

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136L2706

The VACON NXP Common DC Bus active front end unit with order code 136L2706 and type code NXA10306-A0T02SG-A1A200D2CI+FL21 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136L2619

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 136L2619

The VACON NXP Common DC Bus active front end unit with order code 136L2619 and type code NXA04605-A0T02SG-A1A20000E9+FL21+GAAB is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 136L2395

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 7.5 kW 380-500V IP21 - 136L2395

The VACON NXP Common DC Bus brake chopper unit with order code 136L2395 and type code NXB00165-A2T08SV-A1A2000000+DLCN is a 7.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Active Front End Unit 136L1820

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136L1820

The VACON NXP Common DC Bus active front end unit with order code 136L1820 and type code NXA13005-A0T02SG-A1A2B4B500 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136L1600

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 136L1600

The VACON NXP Common DC Bus active front end unit with order code 136L1600 and type code NXA02615-A0T02SG-A1A2B5D2EA is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136L1333

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 136L1333

The VACON NXP Common DC Bus active front end unit with order code 136L1333 and type code NXA04605-A0T02SG-A9A200CQ00 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 136L1083

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 136L1083

The VACON NXP Common DC Bus active front end unit with order code 136L1083 and type code NXA04605-G0T02SG-A1A200CP00+FL26+DLCN is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 136L1010

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 136L1010

The VACON NXP Common DC Bus active front end unit with order code 136L1010 and type code NXA04605-A0T02SG-A1A2B50000+FL23+GALR is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 136L0936

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 136L0936

The VACON NXP Common DC Bus active front end unit with order code 136L0936 and type code NXA01256-A0T02SG-A1A20000E9 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...