  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 136X1353

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136X1353

The VACON NXP Common DC Bus brake chopper unit with order code 136X1353 and type code NXB02615-A0T08SG-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 136X0747

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136X0747

The VACON NXP Common DC Bus active front end unit with order code 136X0747 and type code NXA11505-G0T02SG-A1A3000000+FL26+DLRU is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136X0101

VACON 

VACON NXP Common DC Bus Active Front End Unit 370 kW 380-500V IP00 - 136X0101

The VACON NXP Common DC Bus active front end unit with order code 136X0101 and type code NXA04605-A0T02SG-A1A20000CP is a 370 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 136X0077

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136X0077

The VACON NXP Common DC Bus active front end unit with order code 136X0077 and type code NXA11505-G0T02SG-A1A3000000 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136U9715

VACON 

VACON NXP Common DC Bus Active Front End Unit 138 kW 380-500V IP00 - 136U9715

The VACON NXP Common DC Bus active front end unit with order code 136U9715 and type code NXA02055-G0T02SG-A1A2000000+FL26+DLCN is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 136U8823

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136U8823

The VACON NXP Common DC Bus brake chopper unit with order code 136U8823 and type code NXB13005-A0T08SG-A1A2000000+LS60 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136U8722

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136U8722

The VACON NXP Common DC Bus active front end unit with order code 136U8722 and type code NXA11505-A0T02SG-A1A2000000+FL25+GRID+ARFIF106+LS60+DLES is a 773 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 136U8490

VACON 

VACON NXP Common DC Bus Active Front End Unit 138 kW 380-500V IP00 - 136U8490

The VACON NXP Common DC Bus active front end unit with order code 136U8490 and type code NXA02055-A0T02SG-A1A2D7B5E9 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136U8446

VACON 

VACON NXP Common DC Bus Active Front End Unit 378 kW 525-690V IP00 - 136U8446

The VACON NXP Common DC Bus active front end unit with order code 136U8446 and type code NXA03256-A0T02SO-A1A2000000+FL25+LS60+DLBR is a 378 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 136U8308

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136U8308

The VACON NXP Common DC Bus active front end unit with order code 136U8308 and type code NXA13005-A0T02SG-A1A2D7B9CP is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136U8307

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 136U8307

The VACON NXP Common DC Bus active front end unit with order code 136U8307 and type code NXA11505-A0T02SG-A1A200B9CP is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 136U7881

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136U7881

The VACON NXP Common DC Bus active front end unit with order code 136U7881 and type code NXA10306-G0T02SG-A1A20000CP+FL26+DLRU is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
  • Previous
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • Next