  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 136X6673

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 136X6673

The VACON NXP Common DC Bus brake chopper unit with order code 136X6673 and type code NXB02086-A0T08SG-A1A20000EC+LS60 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136X6768

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136X6768

The VACON NXP Common DC Bus active front end unit with order code 136X6768 and type code NXA10306-A0T02SG-A8A2B1D200 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 136X6672

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136X6672

The VACON NXP Common DC Bus brake chopper unit with order code 136X6672 and type code NXB03005-A0T08SG-A1A20000EC+LS60 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 136X6668

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136X6668

The VACON NXP Common DC Bus active front end unit with order code 136X6668 and type code NXA10306-A0T02SG-A1A2D7B5EC+GRDC+ARFIF106+LS60 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 136X6038

VACON 

VACON NXP Common DC Bus Active Front End Unit 167 kW 525-690V IP00 - 136X6038

The VACON NXP Common DC Bus active front end unit with order code 136X6038 and type code NXA01446-A0T02SG-A1A2D700EC+FL21+GRID+ARFIF106 is a 167 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 136X6055

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 136X6055

The VACON NXP Common DC Bus brake chopper unit with order code 136X6055 and type code NXB02615-A0T08SG-A1A20000EC is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 136X6667

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136X6667

The VACON NXP Common DC Bus active front end unit with order code 136X6667 and type code NXA13005-A0T02SG-A1A2D7B5EC+GRDC+ARFIF106+LS60 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 136X5980

VACON 

VACON NXP Common DC Bus Active Front End Unit 370 kW 380-500V IP00 - 136X5980

The VACON NXP Common DC Bus active front end unit with order code 136X5980 and type code NXA04605-A0T02SG-A1A2B5D200+LS60 is a 370 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Rectifier Unit 136X5143

VACON 

VACON NXP Common DC Bus Rectifier Unit 708 kW 525-690V IP00 - 136X5143

The VACON NXP Common DC Bus rectifier unit with order code 136X5143 and type code NXN06506-X0T0SSV-0000000000+LS60 is a 708 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration...
VACON NXP Common DC Bus Active Front End Unit 136X5139

VACON 

VACON NXP Common DC Bus Active Front End Unit 370 kW 380-500V IP00 - 136X5139

The VACON NXP Common DC Bus active front end unit with order code 136X5139 and type code NXA04605-A0T02SG-A1A2D700E9+UGRD+ARFIF106+LS60 is a 370 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 136X5960

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 136X5960

The VACON NXP Common DC Bus active front end unit with order code 136X5960 and type code NXA10306-A0T02SG-A1A20000CQ+ARFIFF03+GABV is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 136X5177

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 136X5177

The VACON NXP Common DC Bus active front end unit with order code 136X5177 and type code NXA13005-A0T02SG-A8A200D2EA is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
  • Previous
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • Next