  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 137G1490

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137G1490

The VACON NXP Common DC Bus brake chopper unit with order code 137G1490 and type code NXB00455-A2T08SV-A1A20000E6 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137G1197

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 137G1197

The VACON NXP Common DC Bus active front end unit with order code 137G1197 and type code NXA01256-A0T02SG-A1A2D7B1E9+UGRD+ARFIF106 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137G1323

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137G1323

The VACON NXP Common DC Bus active front end unit with order code 137G1323 and type code NXA02615-A0T02SG-A1A2B500C7+FL24+DLCZ is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137G0985

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137G0985

The VACON NXP Common DC Bus brake chopper unit with order code 137G0985 and type code NXB03856-A0T08SG-A1A20000E9+GSNT+SPXE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137G1196

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 137G1196

The VACON NXP Common DC Bus active front end unit with order code 137G1196 and type code NXA01256-A0T02SG-A1A2B1D2E9+UGRD+ARFIF106 is a 145 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137G0950

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137G0950

The VACON NXP Common DC Bus brake chopper unit with order code 137G0950 and type code NXB03856-A0T08SG-A8A20000E9+GSNT+SPXE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Rectifier Unit 137G0769

VACON 

VACON NXP Common DC Bus Rectifier Unit 650 A 525-690V IP00 - 137G0769

The VACON NXP Common DC Bus rectifier unit with order code 137G0769 and type code NXN06506-X0T0NSV-0000000000+GNUL+GNCT+GNKC+GNEA is a 650 A, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137G0698

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137G0698

The VACON NXP Common DC Bus brake chopper unit with order code 137G0698 and type code NXB00125-A2T08SV-A1A2000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It...
VACON NXP Common DC Bus Rectifier Unit 137G0671

VACON 

VACON NXP Common DC Bus Rectifier Unit 650 A 525-690V IP00 - 137G0671

The VACON NXP Common DC Bus rectifier unit with order code 137G0671 and type code NXN06506-X0T0NSV-0000000000+GNUL+GNCT+GNKC+GNUA+GNEA is a 650 A, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137G0576

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 137G0576

The VACON NXP Common DC Bus active front end unit with order code 137G0576 and type code NXA11505-A0T02SG-A1A2000000+ARFIFF05 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Rectifier Unit 137G0550

VACON 

VACON NXP Common DC Bus Rectifier Unit 650 A 525-690V IP00 - 137G0550

The VACON NXP Common DC Bus rectifier unit with order code 137G0550 and type code NXN06506-X0T0SSV-0000000000+GNCT+GNUA is a 650 A, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137G0499

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137G0499

The VACON NXP Common DC Bus active front end unit with order code 137G0499 and type code NXA04605-A0T02SG-A8A2B5D2EA+ARFIFF05+LPC2+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
  • Previous
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • Next