VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137G9971

VACON 

VACON NXP Common DC Bus Active Front End Unit 1067 kW 525-690V IP00 - 137G9971

The VACON NXP Common DC Bus active front end unit with order code 137G9971 and type code NXA09206-G0T02SG-A1A2B500E9+FL26+DLCN is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 137G9941

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137G9941

The VACON NXP Common DC Bus brake chopper unit with order code 137G9941 and type code NXB01055-A2T08SV-A1A20000CP is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137G9638

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137G9638

The VACON NXP Common DC Bus active front end unit with order code 137G9638 and type code NXA04605-A0T02SG-A1A2B500E3+FL23+DLDE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137G9591

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137G9591

The VACON NXP Common DC Bus active front end unit with order code 137G9591 and type code NXA04605-A0T02SG-A100000000+FL21+DLSE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137G9558

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137G9558

The VACON NXP Common DC Bus active front end unit with order code 137G9558 and type code NXA13005-A0T02SG-A1A2000000+ARFIFF05 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137G9223

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137G9223

The VACON NXP Common DC Bus active front end unit with order code 137G9223 and type code NXA04605-A0T02SG-A1B1D7D2E3+FL21+GRDC+ARFIF106+GSNT+SPXE is a 309 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Brake Chopper Unit 137G9212

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137G9212

The VACON NXP Common DC Bus brake chopper unit with order code 137G9212 and type code NXB02615-B0T08SG-A1A200E300+FL21+GSNT+DNOT+SPXE is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137G9107

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137G9107

The VACON NXP Common DC Bus active front end unit with order code 137G9107 and type code NXA03855-A0T02SG-A1A2B500E9+LS60+GABV is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137G9104

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137G9104

The VACON NXP Common DC Bus active front end unit with order code 137G9104 and type code NXA03855-A0T02SG-A1A2000000+GABV is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137G8920

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137G8920

The VACON NXP Common DC Bus active front end unit with order code 137G8920 and type code NXA04605-A0T02SG-A1A2000000+DNOT is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137G8743

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137G8743

The VACON NXP Common DC Bus brake chopper unit with order code 137G8743 and type code NXB02055-A0T08SG-A1A30000E9+FL23 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137G8742

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137G8742

The VACON NXP Common DC Bus active front end unit with order code 137G8742 and type code NXA04605-A0T02SG-A1A3D700E9+FL23+GRID+ARFIF106 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...