<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 137H2656

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137H2656

The VACON NXP Common DC Bus brake chopper unit with order code 137H2656 and type code NXB03856-A0T08SG-A8A20000E9+GACS is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137H2586

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137H2586

The VACON NXP Common DC Bus active front end unit with order code 137H2586 and type code NXA10306-A0T02SG-A8A2B1D2C3+DNOT+DLDE+LPC2+SPXE is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137H2427

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H2427

The VACON NXP Common DC Bus active front end unit with order code 137H2427 and type code NXA04605-A0T02SG-A1A2D7B5E9+ARFIFF03+GSNT+GAIN+LPC2+SPXE is a 309 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 137H2421

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H2421

The VACON NXP Common DC Bus active front end unit with order code 137H2421 and type code NXA04605-A0T02SG-A1A2B50000+ARFIFF03+GSNT+GAIN+LPC2+SPXE is a 309 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Brake Chopper Unit 137H2209

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137H2209

The VACON NXP Common DC Bus brake chopper unit with order code 137H2209 and type code NXB03856-A0T08SG-A8A20000E9+GSNT+GACS+SPXE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137H2123

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H2123

The VACON NXP Common DC Bus active front end unit with order code 137H2123 and type code NXA04605-G0T02SG-A1A2000000+ARFIF106+DLCN+GNKC+GNUA is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137H2058

VACON 

VACON NXP Common DC Bus Active Front End Unit 145 kW 525-690V IP00 - 137H2058

The VACON NXP Common DC Bus active front end unit with order code 137H2058 and type code NXA01256-A0T02SG-A1A2D700E9+FNP02V200+GRID+ARFIF106V103+L0023+GAUG is a 145 kW, three-phase 525-690 V supply,...
VACON NXP Common DC Bus Active Front End Unit 137H1919

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137H1919

The VACON NXP Common DC Bus active front end unit with order code 137H1919 and type code NXA03256-A0T02SG-A1A2B50000+ARFIFF05 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137H1585

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 137H1585

The VACON NXP Common DC Bus active front end unit with order code 137H1585 and type code NXA01685-A0T02SG-A1A2B500E9+DLIT is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137H1398

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 137H1398

The VACON NXP Common DC Bus active front end unit with order code 137H1398 and type code NXA01685-A0T02SG-A1A2000000+FL25+LS60+GSSE+DLES is a 114 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137H1399

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 137H1399

The VACON NXP Common DC Bus active front end unit with order code 137H1399 and type code NXA01685-A0T02SO-A1AFB20000+FL25+LS60+GSSE+DLES is a 114 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137H1291

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137H1291

The VACON NXP Common DC Bus active front end unit with order code 137H1291 and type code NXA13005-G0T02SO-A1A2B800CP+FL26 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
  • Previous
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • Next