<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137H7520

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H7520

The VACON NXP Common DC Bus active front end unit with order code 137H7520 and type code NXA04605-A0T02SG-A1A2000000+FL23+DLDE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137H7323

VACON 

VACON NXP Common DC Bus Active Front End Unit 197 kW 525-690V IP00 - 137H7323

The VACON NXP Common DC Bus active front end unit with order code 137H7323 and type code NXA01706-A0T02SO-A1A200D2E3 is a 197 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137H6876

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H6876

The VACON NXP Common DC Bus active front end unit with order code 137H6876 and type code NXA04605-A0T02SG-A1A20000E9+ARFIFF03 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137H7296

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137H7296

The VACON NXP Common DC Bus active front end unit with order code 137H7296 and type code NXA13005-A0T02SG-A1A20000E3 is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 137H6800

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137H6800

The VACON NXP Common DC Bus brake chopper unit with order code 137H6800 and type code NXB09206-A0T08SG-A1A2000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137H6742

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137H6742

The VACON NXP Common DC Bus brake chopper unit with order code 137H6742 and type code NXB02055-A0T08SG-A1A20000E3+DLIT is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137H6412

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H6412

The VACON NXP Common DC Bus active front end unit with order code 137H6412 and type code NXA04605-A0T02SG-0000000000+ARFIF106 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137H6059

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137H6059

The VACON NXP Common DC Bus brake chopper unit with order code 137H6059 and type code NXB03256-B0T08SO-0000000000+FL26+GSSE is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137H6281

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H6281

The VACON NXP Common DC Bus active front end unit with order code 137H6281 and type code NXA04605-A0T02SG-A1A2D700E9+FL23+GRID+ARFIF106+DLDE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137H6055

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137H6055

The VACON NXP Common DC Bus active front end unit with order code 137H6055 and type code NXA10306-B0T02SO-0000000000+FL26+GSSE is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137H6314

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 137H6314

The VACON NXP Common DC Bus active front end unit with order code 137H6314 and type code NXA01685-A0T02SG-A1A2D70000 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137H6045

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H6045

The VACON NXP Common DC Bus active front end unit with order code 137H6045 and type code NXA04605-A0T02SG-A1A2000000+FL25+ARFIFF05+LS60+DLBR is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
  • Previous
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • Next