VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137L0153

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137L0153

The VACON NXP Common DC Bus active front end unit with order code 137L0153 and type code NXA02615-A0T02SG-A1A3000000+FL25 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137H9667

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 137H9667

The VACON NXP Common DC Bus active front end unit with order code 137H9667 and type code NXA11505-A0T02SG-A1A2000000+GABV+LPC2 is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137H9664

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H9664

The VACON NXP Common DC Bus active front end unit with order code 137H9664 and type code NXA04605-A0T02SG-A1A20000E9+ARFIFF02V141+GABV+LPC2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137H9584

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137H9584

The VACON NXP Common DC Bus active front end unit with order code 137H9584 and type code NXA13005-G0T02SG-A1A2B50000+GSNT+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137H9576

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137H9576

The VACON NXP Common DC Bus active front end unit with order code 137H9576 and type code NXA13005-B0T02SG-A8A200B5E9+GSNT+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 137H9570

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137H9570

The VACON NXP Common DC Bus brake chopper unit with order code 137H9570 and type code NXB01405-B2T08SV-A8A200B8E9+SPXE is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08...
VACON NXP Common DC Bus Active Front End Unit 137H9560

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H9560

The VACON NXP Common DC Bus active front end unit with order code 137H9560 and type code NXA04605-B0T02SG-A8A200B5E9+GSNT+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137H9409

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H9409

The VACON NXP Common DC Bus active front end unit with order code 137H9409 and type code NXA04605-A0T02SG-A1A2000000+FL25+GSSE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137H9406

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H9406

The VACON NXP Common DC Bus active front end unit with order code 137H9406 and type code NXA04605-G0T02SG-A1A2000000+FL25+GSSE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137H9365

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137H9365

The VACON NXP Common DC Bus brake chopper unit with order code 137H9365 and type code NXB00455-G2T08SV-A1A200E900+QGLM+GADN is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Active Front End Unit 137H9404

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137H9404

The VACON NXP Common DC Bus active front end unit with order code 137H9404 and type code NXA04605-A0T02SG-A1A2B40000+FL25+GSSE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137H9361

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137H9361

The VACON NXP Common DC Bus brake chopper unit with order code 137H9361 and type code NXB00725-G2T08SV-A1A200E900+QGLM+GADN is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...