  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 137L1495

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137L1495

The VACON NXP Common DC Bus brake chopper unit with order code 137L1495 and type code NXB01006-A0T08SV-A1A20000E3 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137L1476

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137L1476

The VACON NXP Common DC Bus brake chopper unit with order code 137L1476 and type code NXB01405-A0T08SV-0000000000+QGLM is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR08...
VACON NXP Common DC Bus Active Front End Unit 137L1566

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137L1566

The VACON NXP Common DC Bus active front end unit with order code 137L1566 and type code NXA02615-G0T02SG-A1A2B400E3 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137L1475

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137L1475

The VACON NXP Common DC Bus brake chopper unit with order code 137L1475 and type code NXB00725-A2T08SV-0000000000 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137L1240

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP21 - 137L1240

The VACON NXP Common DC Bus brake chopper unit with order code 137L1240 and type code NXB01006-A2T08SV-A1A20000E3 is a 2 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137L1238

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137L1238

The VACON NXP Common DC Bus active front end unit with order code 137L1238 and type code NXA02615-A0T02SG-A1A2D700E9+UGRD+ARFIF106 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137L1174

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137L1174

The VACON NXP Common DC Bus active front end unit with order code 137L1174 and type code NXA13005-A0T02SG-A8A2B500E9+GSNT+GALR+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137L1170

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137L1170

The VACON NXP Common DC Bus active front end unit with order code 137L1170 and type code NXA13005-A0T02SG-A1A2B500E9+GSNT+GALR+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137L1149

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L1149

The VACON NXP Common DC Bus active front end unit with order code 137L1149 and type code NXA04605-A0T02SG-A1A2B50000+ARFIFF02V141 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137L0984

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137L0984

The VACON NXP Common DC Bus active front end unit with order code 137L0984 and type code NXA03855-A0T02SG-A8A2B500E9+ARFIFF05+GSNT+GAAB+LPC2+SPXE is a 259 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 137L0862

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L0862

The VACON NXP Common DC Bus active front end unit with order code 137L0862 and type code NXA04605-A0T02SG-A1A2B50000+GSNT+GADN+LPC2+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137L0843

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137L0843

The VACON NXP Common DC Bus active front end unit with order code 137L0843 and type code NXA02615-A0T02SG-0000000000 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
  • Previous
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • Next