<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 137L5920

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137L5920

The VACON NXP Common DC Bus brake chopper unit with order code 137L5920 and type code NXB04605-A0T08SG-0000000000 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137L5907

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137L5907

The VACON NXP Common DC Bus active front end unit with order code 137L5907 and type code NXA02615-A0T02SG-A1A2B5D2EA+FL23+GRDC+ARFIF106+DLDE+LPC2 is a 175 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 137L5730

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L5730

The VACON NXP Common DC Bus active front end unit with order code 137L5730 and type code NXA04605-A0T02SG-A8A2B500E9 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137L5348

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L5348

The VACON NXP Common DC Bus active front end unit with order code 137L5348 and type code NXA04605-A0T02SG-ANA2D7B5E9+ARFIFF03 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137L5042

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L5042

The VACON NXP Common DC Bus active front end unit with order code 137L5042 and type code NXA04605-A0T02SG-A8A2BH00E9+DNOT+DLIT is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137L4628

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137L4628

The VACON NXP Common DC Bus brake chopper unit with order code 137L4628 and type code NXB03856-A0T08SG-A1A2000000+FL26+LS60+GNUA+GNEA is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137L4149

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137L4149

The VACON NXP Common DC Bus brake chopper unit with order code 137L4149 and type code NXB01706-G0T08SG-A8A2000000+GADN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137L4065

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L4065

The VACON NXP Common DC Bus active front end unit with order code 137L4065 and type code NXA04605-A0T02SG-A1A200CI00+FL23+ARFIFF02V141+DLDE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Brake Chopper Unit 137L4062

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137L4062

The VACON NXP Common DC Bus brake chopper unit with order code 137L4062 and type code NXB02086-G0T08SG-A8A3A500E2 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137L3864

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137L3864

The VACON NXP Common DC Bus active front end unit with order code 137L3864 and type code NXA03256-A0T02SG-A1A2D700EC+GRID+ARFIF106 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137L3846

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137L3846

The VACON NXP Common DC Bus active front end unit with order code 137L3846 and type code NXA03256-A0T02SG-A1A20000E6 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137L3842

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137L3842

The VACON NXP Common DC Bus active front end unit with order code 137L3842 and type code NXA03855-G0T02SG-A1A2B50000+FL26+DLCN+GACS is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
  • Previous
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • Next