VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 137L6700

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137L6700

The VACON NXP Common DC Bus brake chopper unit with order code 137L6700 and type code NXB00315-G2T08SV-0000000000+FL26+DLCN is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Active Front End Unit 137L6441

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 137L6441

The VACON NXP Common DC Bus active front end unit with order code 137L6441 and type code NXA11505-A0T02SG-A1A20000E9+ARFIFF05+DLES is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137L6439

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137L6439

The VACON NXP Common DC Bus brake chopper unit with order code 137L6439 and type code NXB00455-A2T08SV-A1A200BHE9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137L6362

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L6362

The VACON NXP Common DC Bus active front end unit with order code 137L6362 and type code NXA04605-A0T02SG-A1A2000000+ARFIFF05+LPC2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137L6317

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L6317

The VACON NXP Common DC Bus active front end unit with order code 137L6317 and type code NXA04605-A0T02SG-A1A2000000+ARFIF106+LPC2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137L6296

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137L6296

The VACON NXP Common DC Bus active front end unit with order code 137L6296 and type code NXA02615-A0T02SG-A1A20000E3 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137L6194

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137L6194

The VACON NXP Common DC Bus brake chopper unit with order code 137L6194 and type code NXB03856-A0T08SG-A1AF00D2E5 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137L6280

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137L6280

The VACON NXP Common DC Bus active front end unit with order code 137L6280 and type code NXA10306-A0T02SG-A1A2B5D2EA+FL23+ARFIFF05+DLDE+LPC2 is a 1194 kW, three-phase 525-690 V supply, IP00...
VACON NXP Common DC Bus Brake Chopper Unit 137L6128

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137L6128

The VACON NXP Common DC Bus brake chopper unit with order code 137L6128 and type code NXB00385-A2T08SV-A1A20000E6+QGLM is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Active Front End Unit 137L6097

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137L6097

The VACON NXP Common DC Bus active front end unit with order code 137L6097 and type code NXA03855-A0T02SG-A100D7B5E9 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137L5927

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L5927

The VACON NXP Common DC Bus active front end unit with order code 137L5927 and type code NXA04605-A0T02SG-A1A200CI00+ARFIFF05+LPC2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137L5925

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137L5925

The VACON NXP Common DC Bus active front end unit with order code 137L5925 and type code NXA10306-A0T02SG-A1A2000000+ARFIFF05+LPC2 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame...