<
<
  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Brake Chopper Unit 137N3088

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137N3088

The VACON NXP Common DC Bus brake chopper unit with order code 137N3088 and type code NXB02616-G0T08SG-A1A2000000+FL26+DLCN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137N3090

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137N3090

The VACON NXP Common DC Bus active front end unit with order code 137N3090 and type code NXA13005-G0T02SG-A1A2B50000+GSNT+EMAR+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137N2998

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137N2998

The VACON NXP Common DC Bus active front end unit with order code 137N2998 and type code NXA02615-A0T02SG-A1A200CQ00+FL25+GRID+ARFIF106+LS60+DLES+LPC2 is a 175 kW, three-phase 380-500 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 137N2798

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137N2798

The VACON NXP Common DC Bus active front end unit with order code 137N2798 and type code NXA10306-A0T02SG-A8A2A50000+GACS is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137N2795

VACON 

VACON NXP Common DC Bus Active Front End Unit 1067 kW 525-690V IP00 - 137N2795

The VACON NXP Common DC Bus active front end unit with order code 137N2795 and type code NXA09206-A0T02SG-A8A2A50000+GACS is a 1067 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 137N1534

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137N1534

The VACON NXP Common DC Bus brake chopper unit with order code 137N1534 and type code NXB00455-A2T08SV-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137N1723

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 137N1723

The VACON NXP Common DC Bus active front end unit with order code 137N1723 and type code NXA01685-A0T02SG-A1A2D7E600+FL23+GRID+ARFIF106+DLDE is a 114 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137N1347

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137N1347

The VACON NXP Common DC Bus active front end unit with order code 137N1347 and type code NXA10306-A0T02SG-A1A2B50000+FL23 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Brake Chopper Unit 137N2616

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137N2616

The VACON NXP Common DC Bus brake chopper unit with order code 137N2616 and type code NXB00385-A2T08SV-A1A20000E7 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137N2399

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137N2399

The VACON NXP Common DC Bus brake chopper unit with order code 137N2399 and type code NXB00095-A2T08SV-A1A20000E9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It...
VACON NXP Common DC Bus Brake Chopper Unit 137N2667

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137N2667

The VACON NXP Common DC Bus brake chopper unit with order code 137N2667 and type code NXB00125-A2T08SV-A1A20000E7+QGLM is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Common DC Bus Active Front End Unit 137N1423

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137N1423

The VACON NXP Common DC Bus active front end unit with order code 137N1423 and type code NXA13005-A0T02SG-ANA200B5E9+GSNT+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
  • Previous
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • Next