VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137N6690

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137N6690

The VACON NXP Common DC Bus active front end unit with order code 137N6690 and type code NXA04605-G0T02SG-A1A2B500E2+GSNT+EMAR+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137N6591

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137N6591

The VACON NXP Common DC Bus active front end unit with order code 137N6591 and type code NXA03256-A0T02SG-A8A200D2CP is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137N6414

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137N6414

The VACON NXP Common DC Bus brake chopper unit with order code 137N6414 and type code NXB00875-A2T08SV-A1A20000E9+DLFR is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Common DC Bus Active Front End Unit 137N6304

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137N6304

The VACON NXP Common DC Bus active front end unit with order code 137N6304 and type code NXA04605-A0T02SG-A1A200B5E2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137N6095

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137N6095

The VACON NXP Common DC Bus active front end unit with order code 137N6095 and type code NXA03256-A0T02SG-A1A2B500E9+GSNT+GALR+LPC2+SPXE is a 377 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137N6007

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137N6007

The VACON NXP Common DC Bus active front end unit with order code 137N6007 and type code NXA04605-A0T02SG-ANAFA5CIB4 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137N6005

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137N6005

The VACON NXP Common DC Bus brake chopper unit with order code 137N6005 and type code NXB04605-A0T08SG-A1A200CI00 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137N5414

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137N5414

The VACON NXP Common DC Bus active front end unit with order code 137N5414 and type code NXA03855-A0T02SG-A1A2D700E9+DLFR is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137N5691

VACON 

VACON NXP Common DC Bus Active Front End Unit 303 kW 525-690V IP00 - 137N5691

The VACON NXP Common DC Bus active front end unit with order code 137N5691 and type code NXA02616-G0T02SG-A8A2B500E9+ARFIFF02V141+GACS is a 303 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137N5300

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137N5300

The VACON NXP Common DC Bus active front end unit with order code 137N5300 and type code NXA04605-A0T02SG-A1A20000E9+ARFIFF05+GSSE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137N5274

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137N5274

The VACON NXP Common DC Bus active front end unit with order code 137N5274 and type code NXA03256-A0T02SG-A1A200D2CP is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137N5270

VACON 

VACON NXP Common DC Bus Active Front End Unit 138 kW 380-500V IP00 - 137N5270

The VACON NXP Common DC Bus active front end unit with order code 137N5270 and type code NXA02055-A0T02SG-A8A200E200+ARFIFF02V123+DLCN+GACS is a 138 kW, three-phase 380-500 V supply, IP00 enclosure,...