  • Search

VACON NXP Common DC Bus

  • Home
  • Vacon Drives
  • VACON NXP
  • VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACONĀ® NXP Common DC Bus modules (active front-end, rectifier, brake chopper and inverter units) build multi-drive systems that share one DC bus. Braking energy is reused between drives or fed back to the grid, reducing energy cost and cabinet size.

VACONĀ® NXP Common DC Bus: technical overview

Easy integration – ultimate flexibility

The VACON® NXP range of common DC bus drive products includes a number of active front-ends, inverters and brake chopper units. They ensure all energy within a system is effectively utilized and redistributed.

Common DC bus components can be used in many different combinations. In a regenerative DC bus system, the active front-end unit generates power back to the mains network. This is suitable for processes where braking is needed often and the braking power is relatively high. In a non-regenerative system, braking power is redistributed to other drives in the system and possible excess power can be dissipated as heat using an optional brake chopper and brake resistors. This is ideal for small production lines where braking is needed less often.

 

Supply voltages and power range 

Inverter units
3 x 380-500 V...1.5-1850 kW
3 x 525-690 V...3-2000 kW

 

Features and benefits

  • Reduced energy costs as regenerative front-end feeds excess braking energy back into the network 
  • Investment costs are low as a result of reduced power cabling and installation time
  • Cost and space savings as optimized module design reduces need for additional engineering and cabinet space
  • Lower system complexity thanks to five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Improvements in drive line-up tolerance to voltage dips/sags and minimized harmonic distortion are possible as a result of the active front-end unit
  • Easy installation of compact option boards

 

Applications

Continuous web and roller table systems, winders and unwinders, cranes, hoists, gantry and trolley drives, centrifuges, winches, conveyors and excavators.

Sub Categories

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 380-500 V

VACON NXP Common DC Bus 525-690 V

VACON NXP Common DC Bus 525-690 V

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137N9208

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137N9208

The VACON NXP Common DC Bus active front end unit with order code 137N9208 and type code NXA03256-A0T02SG-A1B1D7E6E9+GRID+ARFIF106+GSNT+DNOT+LPC2+SPXE is a 377 kW, three-phase 525-690 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 137N8952

VACON 

VACON NXP Common DC Bus Active Front End Unit 167 kW 525-690V IP00 - 137N8952

The VACON NXP Common DC Bus active front end unit with order code 137N8952 and type code NXA01446-A0T02SG-A8A200B1E9+ARFIFF05+GSNT+DLES+GABV+LPC2+SPXE is a 167 kW, three-phase 525-690 V supply, IP00...
VACON NXP Common DC Bus Active Front End Unit 137N8717

VACON 

VACON NXP Common DC Bus Active Front End Unit 874 kW 380-500V IP00 - 137N8717

The VACON NXP Common DC Bus active front end unit with order code 137N8717 and type code NXA13005-A0T02SG-A8A2B5D2E9+GSNT+SPXE is a 874 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137N8701

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137N8701

The VACON NXP Common DC Bus active front end unit with order code 137N8701 and type code NXA02615-A0T02SG-A1A2B500E9+ARFIFF05+DLFR+EMAR is a 175 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137N8697

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137N8697

The VACON NXP Common DC Bus active front end unit with order code 137N8697 and type code NXA10306-A0T02SG-A9A2000000 is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI13...
VACON NXP Common DC Bus Active Front End Unit 137N8514

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137N8514

The VACON NXP Common DC Bus active front end unit with order code 137N8514 and type code NXA04605-A0T02SG-A1A2B5E900 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137N8207

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137N8207

The VACON NXP Common DC Bus active front end unit with order code 137N8207 and type code NXA03256-A0T02SG-A1A2B500E9+ARFIFF05+DLFI is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137N8126

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 137N8126

The VACON NXP Common DC Bus active front end unit with order code 137N8126 and type code NXA01685-A0T02SG-A1A2D700E9+FL24+GRID+ARFIF106 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137N7936

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137N7936

The VACON NXP Common DC Bus active front end unit with order code 137N7936 and type code NXA02615-A0T02SG-A1AFBH00EC+FL23+ARFIFF02V141+DLDE+GNUL+GNKC+GNUA+GNEA is a 175 kW, three-phase 380-500 V...
VACON NXP Common DC Bus Active Front End Unit 137N7790

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137N7790

The VACON NXP Common DC Bus active front end unit with order code 137N7790 and type code NXA10306-A0T02SG-A1A2D7E900+MASS+ARFIFF03+EMAR is a 1194 kW, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137N7833

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137N7833

The VACON NXP Common DC Bus active front end unit with order code 137N7833 and type code NXA04605-A0T02SG-A1A2B500E9+GABV is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137N7793

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137N7793

The VACON NXP Common DC Bus active front end unit with order code 137N7793 and type code NXA10306-A0T02SG-A1A2D7E900+MASS+ARFIFF03+LS60+EMAR is a 1194 kW, three-phase 525-690 V supply, IP00...
  • Previous
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • Next