VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L9649

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 361 kW 380-500V IP00 - 136L9649

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L9649 and type code NXA05905-A0T02WG-A8A2D7B5CI+FL23+ARFIFF05+GALR is a 361 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L9570

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 361 kW 380-500V IP00 - 136L9570

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L9570 and type code NXA05905-A0T02WG-A8A2B500CI+FL23+ARFIFF05+GALR is a 361 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L9466

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 687 kW 525-690V IP00 - 136L9466

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L9466 and type code NXA06506-A0T02WG-A1A2B50000+FL23+GALR is a 687 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L9464

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 475 kW 380-500V IP00 - 136L9464

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L9464 and type code NXA05905-A0T02WG-A1A20000CP is a 475 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L9303

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 361 kW 380-500V IP00 - 136L9303

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L9303 and type code NXA05905-A0T02WG-A8A2B500CI is a 361 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L8437

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1511 kW 525-690V IP00 - 136L8437

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L8437 and type code NXA13006-A0T02WG-A8A2D700E9 is a 1511 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 136L8094

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 372 kW 525-690V IP00 - 136L8094

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 136L8094 and type code NXB01706-A0T08WG-A1A20000CI is a 372 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L6770

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1511 kW 525-690V IP00 - 136L6770

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L6770 and type code NXA13006-A0T02WG-A9A200E900 is a 1511 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 136L5680

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 316 kW 380-500V IP00 - 136L5680

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 136L5680 and type code NXB02615-A0T08WV-A1A20000E9+DLES is a 316 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L5331

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1070 kW 525-690V IP00 - 136L5331

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L5331 and type code NXA09206-A0T02WG-A8A20000CI is a 1070 kW, three-phase 525-690 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L5216

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 872 kW 525-690V IP00 - 136L5216

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L5216 and type code NXA07506-A0T02WO-A1A2B5D2EC+FL23+ARFIFF05+DLDE+LPC2 is a 872 kW, three-phase...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 136L5317

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 475 kW 380-500V IP00 - 136L5317

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 136L5317 and type code NXA05905-A0T02WG-A1A2B500CI+FL23+DLDE is a 475 kW, three-phase 380-500 V supply,...