VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC Drive 137N6058

VACON 

VACON NXP Air Cooled AC Drive 90 kW 380-500V IP21 - 137N6058

The VACON NXP Air Cooled AC Drive with order code 137N6058 and type code NXP01685-A2H1SSV-A1AF0000E9+QGLM+DLFR is a 90 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It...
VACON NXP Air Cooled AC Drive 137N6057

VACON 

VACON NXP Air Cooled AC Drive 15 kW 525-690V IP54 - 137N6057

The VACON NXP Air Cooled AC Drive with order code 137N6057 and type code NXP00186-A5T0SSV-A1A3000000+LS60+DPAP is a 15 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR06 configuration. It...
VACON NXP Air Cooled AC Drive 137N6053

VACON 

VACON NXP Air Cooled AC Drive 5.5 kW 380-500V IP21 - 137N6053

The VACON NXP Air Cooled AC Drive with order code 137N6053 and type code NXP00125-A2H1SSV-A1AF0000E5+QGLM+DPAP+DLNL is a 5.5 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration...
VACON NXP Air Cooled AC Drive 137N6052

VACON 

VACON NXP Air Cooled AC Drive 22 kW 525-690V IP21 - 137N6052

The VACON NXP Air Cooled AC Drive with order code 137N6052 and type code NXP00276-A2T0SSV-A1A2000000 is a 22 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR06 configuration. It is rated 27...
VACON NXP Air Cooled AC Drive 137N6046

VACON 

VACON NXP Air Cooled AC Drive 5.5 kW 230V IP21 - 137N6046

The VACON NXP Air Cooled AC Drive with order code 137N6046 and type code NXP00252-A2H1SSV-A100000000 is a 5.5 kW, three-phase 230 V supply, IP21 enclosure, frame FR05 configuration. It is rated 25 A...
VACON NXP Air Cooled AC Drive 137N6045

VACON 

VACON NXP Air Cooled AC Drive 55 kW 380-500V IP21 - 137N6045

The VACON NXP Air Cooled AC Drive with order code 137N6045 and type code NXP01055-A2T1SSV-A1AF00D2E7+APFIFF09 is a 55 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It is...
VACON NXP Air Cooled AC Drive 137N6033

VACON 

VACON NXP Air Cooled AC Drive 45 kW 380-500V IP21 - 137N6033

The VACON NXP Air Cooled AC Drive with order code 137N6033 and type code NXP00875-A2T0SSV-A9A2000000+QGLM is a 45 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It is...
VACON NXP Air Cooled AC Drive 137N6039

VACON 

VACON NXP Air Cooled AC Drive 30 kW 525-690V IP21 - 137N6039

The VACON NXP Air Cooled AC Drive with order code 137N6039 and type code NXP00346-A2T0SSV-A1A2000000 is a 30 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR06 configuration. It is rated 34...
VACON NXP Air Cooled AC Drive 137N6032

VACON 

VACON NXP Air Cooled AC Drive 18.5 kW 380-500V IP21 - 137N6032

The VACON NXP Air Cooled AC Drive with order code 137N6032 and type code NXP00385-A2H1SSV-A1A20000E9+DPAP+DLFR is a 18.5 kW (25 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Air Cooled AC Drive 137N6013

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP00 - 137N6013

The VACON NXP Air Cooled AC Drive with order code 137N6013 and type code NXP03855-A0T0SSB-A1A200E200+FL21+DLCN is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It...
VACON NXP Air Cooled AC Drive 137N6012

VACON 

VACON NXP Air Cooled AC Drive 132 kW 380-500V IP21 - 137N6012

The VACON NXP Air Cooled AC Drive with order code 137N6012 and type code NXP02615-A2H0SSG-A1A200E200+FL21+DPAP+DLCN is a 132 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR09 configuration...
VACON NXP Air Cooled AC Drive 137N6017

VACON 

VACON NXP Air Cooled AC Drive 1.1 kW 380-500V IP21 - 137N6017

The VACON NXP Air Cooled AC Drive with order code 137N6017 and type code NXP00035-A2H1SSV-A1A20000E7 is a 1.1 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 3...