  • Search

VACON NXP

  • Home
  • Vacon Drives
  • VACON NXP

VACON NXP

VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0727

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 448 kW 380-500V IP00 - 137H0727

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0727 and type code NXA07305-A0T02WG-A8A3D7B1E9+FL21+MASG+ARFIFF03+LS60+GSSE+GAAB+GNKC+GNUA+GNEA is a...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0534

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 282 kW 380-500V IP00 - 137H0534

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0534 and type code NXA04605-A0T02PG-A1B5D7E6E9+MASG+ARFIFF03+EMAR is a 282 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0533

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 160 kW 380-500V IP00 - 137H0533

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0533 and type code NXA02615-A0T02PG-A1B5D7E6E9+MASG+ARFIFF03+EMAR is a 160 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0532

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 137H0532

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0532 and type code NXA02055-A0T02PG-A1B5D7E6E9+MASG+ARFIFF03+EMAR is a 125 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0531

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 103 kW 380-500V IP00 - 137H0531

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0531 and type code NXA01685-A0T02PG-A1B5D7E6E9+MASG+ARFIFF03+EMAR is a 103 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0506

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 319 kW 380-500V IP00 - 137H0506

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0506 and type code NXA05205-A0T02PG-A1A2BCE6E9+ARFIFF30+EMAR is a 319 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0505

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 502 kW 380-500V IP00 - 137H0505

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0505 and type code NXA08205-A0T02PG-A1A2BCE6E9+ARFIFF30+EMAR is a 502 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0504

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 448 kW 380-500V IP00 - 137H0504

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0504 and type code NXA07305-A0T02PG-A1A2BCE6E9+ARFIFF30+EMAR is a 448 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0413

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 282 kW 380-500V IP00 - 137H0413

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0413 and type code NXA04605-A0T02PG-A1A2BCE6E9+ARFIFF30+GAIN is a 282 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0091

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 448 kW 380-500V IP00 - 137H0091

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0091 and type code NXA07305-A0T02WG-A1A3D70000+MASG+ARFIFF03 is a 448 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0092

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 282 kW 380-500V IP00 - 137H0092

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0092 and type code NXA04605-A0T02WG-A1A3000000 is a 282 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137H0417

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 137H0417

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137H0417 and type code NXA20605-A0T02WG-A1A2D7B5E9+MASG+ARFIFF03+DLFR+GABV is a 1262 kW, three-phase...
  • Previous
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • Next