VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC Drive 137N6210

VACON 

VACON NXP Air Cooled AC Drive 110 kW 380-500V IP21 - 137N6210

The VACON NXP Air Cooled AC Drive with order code 137N6210 and type code NXP02055-A2T0SSV-A1A3000000 is a 110 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N6190

VACON 

VACON NXP Air Cooled AC Drive 110 kW 380-500V IP21 - 137N6190

The VACON NXP Air Cooled AC Drive with order code 137N6190 and type code NXP02055-A2T0SSV-A1A2000000+APITF058 is a 110 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It...
VACON NXP Air Cooled AC Drive 137N6186

VACON 

VACON NXP Air Cooled AC Drive 75 kW 380-500V IP21 - 137N6186

The VACON NXP Air Cooled AC Drive with order code 137N6186 and type code NXP01405-A2T0SSV-A1A2000000+APITF058 is a 75 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It is...
VACON NXP Air Cooled AC Drive 137N6188

VACON 

VACON NXP Air Cooled AC Drive 90 kW 380-500V IP21 - 137N6188

The VACON NXP Air Cooled AC Drive with order code 137N6188 and type code NXP01685-A2T0SSV-A1A2000000+APITF058 is a 90 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR08 configuration. It is...
VACON NXP Air Cooled AC Drive 137N6184

VACON 

VACON NXP Air Cooled AC Drive 1.1 kW 380-500V IP21 - 137N6184

The VACON NXP Air Cooled AC Drive with order code 137N6184 and type code NXP00035-A2T1SSV-A1A200E300+GNUL+GNCT+GNKC+GNUA+GNEA is a 1.1 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Air Cooled AC Drive 137N6183

VACON 

VACON NXP Air Cooled AC Drive 2.2 kW 380-500V IP21 - 137N6183

The VACON NXP Air Cooled AC Drive with order code 137N6183 and type code NXP00055-A2T1SSV-A1A200E300+GNUL+GNCT+GNKC+GNUA+GNEA is a 2.2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04...
VACON NXP Air Cooled AC Drive 137N6174

VACON 

VACON NXP Air Cooled AC Drive 315 kW 525-690V IP00 - 137N6174

The VACON NXP Air Cooled AC Drive with order code 137N6174 and type code NXP03256-A0T0SSG-A1A20000E9 is a 315 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137N6172

VACON 

VACON NXP Air Cooled AC Drive 7.5 kW 525-690V IP21 - 137N6172

The VACON NXP Air Cooled AC Drive with order code 137N6172 and type code NXP00106-A2T0SSV-A1A2000000+QGLM+FL23+DPAP is a 7.5 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR06 configuration...
VACON NXP Air Cooled AC Drive 137N6158

VACON 

VACON NXP Air Cooled AC Drive 560 kW 525-690V IP00 - 137N6158

The VACON NXP Air Cooled AC Drive with order code 137N6158 and type code NXP05906-G0N0TSG-ANA200E200+FL26+DLCN is a 560 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR11 configuration. It...
VACON NXP Air Cooled AC Drive 137N6149

VACON 

VACON NXP Air Cooled AC Drive 315 kW 380-500V IP00 - 137N6149

The VACON NXP Air Cooled AC Drive with order code 137N6149 and type code NXP05905-G0T0SSG-A8B1D700E2+GACS is a 315 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR11 configuration. It is...
VACON NXP Air Cooled AC Drive 137N6146

VACON 

VACON NXP Air Cooled AC Drive 1.1 kW 380-500V IP21 - 137N6146

The VACON NXP Air Cooled AC Drive with order code 137N6146 and type code NXP00035-A2H1SSV-A1A200B200 is a 1.1 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is rated 3...
VACON NXP Air Cooled AC Drive 137N6127

VACON 

VACON NXP Air Cooled AC Drive 355 kW 380-500V IP00 - 137N6127

The VACON NXP Air Cooled AC Drive with order code 137N6127 and type code NXP06505-A0T0TSO-A1A2000000+FL25+LS60+DLES is a 355 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR11 configuration...