  • Search

VACON NXP

  • Home
  • Vacon Drives
  • VACON NXP

VACON NXP

VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L4064

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1796 kW 525-690V IP00 - 137L4064

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L4064 and type code NXA17006-G0T02WG-A8A3D700E2+MASG+ARFIFF03 is a 1796 kW, three-phase 525-690 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L4063

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1586 kW 525-690V IP00 - 137L4063

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L4063 and type code NXA15006-G0T02WG-A8A3A500E2+ARFIFF30 is a 1586 kW, three-phase 525-690 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L3916

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1005 kW 380-500V IP00 - 137L3916

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L3916 and type code NXA16405-G0T02WG-A8A3D700E2+MASG+ARFIFF03 is a 1005 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L3665

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1247 kW 525-690V IP00 - 137L3665

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L3665 and type code NXA11806-A0T02WG-A1A20000E9+GSNT+EMAR+LPC2+SPXE is a 1247 kW, three-phase 525-690...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137L2542

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 181 kW 380-500V IP00 - 137L2542

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137L2542 and type code NXB01685-A0T08PG-A1A2000000+FL23+DNOT+DLDE is a 181 kW, three-phase 380-500 V supply,...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L2598

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 125 kW 380-500V IP00 - 137L2598

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L2598 and type code NXA02055-A0T02WG-A1B8D700E9+MASG+ARFIFF03 is a 125 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L3120

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 563 kW 380-500V IP00 - 137L3120

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L3120 and type code NXA09205-A0T02WG-A1A2D700E9+MASG+ARFIFF03 is a 563 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L2540

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 160 kW 380-500V IP00 - 137L2540

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L2540 and type code NXA02615-A0T02PG-A1A200D2EC+FL23+ARFIFF05+DNOT is a 160 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137L2472

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 496 kW 380-500V IP00 - 137L2472

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137L2472 and type code NXB04605-G0T08WG-A8A20000E3+GACS is a 496 kW, three-phase 380-500 V supply, IP00...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L2471

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 137L2471

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L2471 and type code NXA20605-G0T02WG-A8B1D7D2E3+ARFIFF03+GACS is a 1262 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 137L2470

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Active Front End Unit 1262 kW 380-500V IP00 - 137L2470

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled active front end unit with order code 137L2470 and type code NXA20605-G0T02WG-A8B100D2E3+ARFIFF30+GACS is a 1262 kW, three-phase 380-500 V...
VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 137L2406

VACON 

VACON NXP Liquid Cooled Common DC Bus Liquid-Cooled Brake Chopper Unit 324 kW 380-500V IP00 - 137L2406

The VACON NXP Liquid Cooled Common DC Bus liquid-cooled brake chopper unit with order code 137L2406 and type code NXB03005-A0T08PG-A1A20000E9+FL23+DLDE is a 324 kW, three-phase 380-500 V supply, IP00...
  • Previous
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • Next