VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC Drive 137X2242

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP00 - 137X2242

The VACON NXP Air Cooled AC Drive with order code 137X2242 and type code NXP03855-A0N0TSB-A1A20000E3 is a 200 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR10 configuration. It is rated...
VACON NXP Air Cooled AC Drive 137X2224

VACON 

VACON NXP Air Cooled AC Drive 75 kW 525-690V IP54 - 137X2224

The VACON NXP Air Cooled AC Drive with order code 137X2224 and type code NXP00806-A5T0SSV-A1A2B500E5 is a 75 kW, three-phase 525-690 V supply, IP54 enclosure, frame FR08 configuration. It is rated 80...
VACON NXP Air Cooled AC Drive 137X2214

VACON 

VACON NXP Air Cooled AC Drive 55 kW 380-500V IP21 - 137X2214

The VACON NXP Air Cooled AC Drive with order code 137X2214 and type code NXP01055-A2H1SSV-A1AFB1B200+QGLM+FL21+DPAP+DLSE is a 55 kW (75 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR07...
VACON NXP Air Cooled AC Drive 137X2213

VACON 

VACON NXP Air Cooled AC Drive 110 kW 380-500V IP54 - 137X2213

The VACON NXP Air Cooled AC Drive with order code 137X2213 and type code NXP02055-A5T0SSV-A1A2000000+QGLM+GALR is a 110 kW (150 HP), three-phase 380-500 V supply, IP54 enclosure, frame FR08...
VACON NXP Air Cooled AC Drive 137X2207

VACON 

VACON NXP Air Cooled AC Drive 160 kW 525-690V IP21 - 137X2207

The VACON NXP Air Cooled AC Drive with order code 137X2207 and type code NXP01706-A2L0SSG-A1A2B4BHE3+DLIT is a 160 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR09 configuration. It is...
VACON NXP Air Cooled AC Drive 137X2201

VACON 

VACON NXP Air Cooled AC Drive 132 kW 525-690V IP21 - 137X2201

The VACON NXP Air Cooled AC Drive with order code 137X2201 and type code NXP01446-A2L0SSG-A1A3B50000+FL21+DPAP+DLFI is a 132 kW, three-phase 525-690 V supply, IP21 enclosure, frame FR09 configuration...
VACON NXP Air Cooled AC Drive 137X2198

VACON 

VACON NXP Air Cooled AC Drive 30 kW 525-690V IP54 - 137X2198

The VACON NXP Air Cooled AC Drive with order code 137X2198 and type code NXP00346-A5L1SSV-A1A3000000+QGLM+FL23+LS60+DPAP+DLDE is a 30 kW (40 HP), three-phase 525-690 V supply, IP54 enclosure, frame...
VACON NXP Air Cooled AC Drive 137X2193

VACON 

VACON NXP Air Cooled AC Drive 11 kW 380-500V IP21 - 137X2193

The VACON NXP Air Cooled AC Drive with order code 137X2193 and type code NXP00225-A2H1SSV-A9A3000000+QGLM+FL23+DPAP+DLDE is a 11 kW (15 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR05...
VACON NXP Air Cooled AC Drive 137X2174

VACON 

VACON NXP Air Cooled AC Drive 30 kW 380-500V IP21 - 137X2174

The VACON NXP Air Cooled AC Drive with order code 137X2174 and type code NXP00615-A2H1SSV-A1A2D700E9+QGLM+MASG+ARFIFF03 is a 30 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Air Cooled AC Drive 137X2184

VACON 

VACON NXP Air Cooled AC Drive 55 kW 380-500V IP21 - 137X2184

The VACON NXP Air Cooled AC Drive with order code 137X2184 and type code NXP01055-A2H1SSV-A1A2000000+FL26+DLCN is a 55 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR07 configuration. It...
VACON NXP Air Cooled AC Drive 137X2169

VACON 

VACON NXP Air Cooled AC Drive 800 kW 380-500V IP00 - 137X2169

The VACON NXP Air Cooled AC Drive with order code 137X2169 and type code NXP14505-A0T0SSG-A1A20000E9+APCNF005+GSNT+SPXE is a 800 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR13...
VACON NXP Air Cooled AC Drive 137X2163

VACON 

VACON NXP Air Cooled AC Drive 45 kW 380-500V IP54 - 137X2163

The VACON NXP Air Cooled AC Drive with order code 137X2163 and type code NXP00875-A5T1SSV-A1A3A4B500+QGLM+FL21+APFIFF09+DPAP is a 45 kW (60 HP), three-phase 380-500 V supply, IP54 enclosure, frame...