  • Search

VACON NXP

  • Home
  • Vacon Drives
  • VACON NXP

VACON NXP

VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Air Cooled AC Drive 137X2603

VACON 

VACON NXP Air Cooled AC Drive 3 kW 380-500V IP21 - 137X2603

The VACON NXP Air Cooled AC Drive with order code 137X2603 and type code NXP00075-A2T1SSV-A1A2000000+FL25+LS60+DLBR is a 3 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration...
VACON NXP Air Cooled AC Drive 137X2584

VACON 

VACON NXP Air Cooled AC Drive 30 kW 380-500V IP21 - 137X2584

The VACON NXP Air Cooled AC Drive with order code 137X2584 and type code NXP00615-A2H1SSV-A1AF00E200+DPAP+DLIT is a 30 kW (40 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Air Cooled AC Drive 137X2581

VACON 

VACON NXP Air Cooled AC Drive 37 kW 525-690V IP21 - 137X2581

The VACON NXP Air Cooled AC Drive with order code 137X2581 and type code NXP00416-A2T0SSV-A1A3B50000 is a 37 kW (50 HP), three-phase 525-690 V supply, IP21 enclosure, frame FR07 configuration. It is...
VACON NXP Air Cooled AC Drive 137X2576

VACON 

VACON NXP Air Cooled AC Drive 90 kW 380-500V IP54 - 137X2576

The VACON NXP Air Cooled AC Drive with order code 137X2576 and type code NXP01685-A5T0SSV-A1A2B2B4E9+QGLM+APFIFF09+EMAR is a 90 kW (125 HP), three-phase 380-500 V supply, IP54 enclosure, frame FR08...
VACON NXP Air Cooled AC Drive 137X2541

VACON 

VACON NXP Air Cooled AC Drive 18.5 kW 380-500V IP54 - 137X2541

The VACON NXP Air Cooled AC Drive with order code 137X2541 and type code NXP00385-G5T2SSV-A8A2A500B5+FL26+DPAP+DLCN is a 18.5 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR06...
VACON NXP Air Cooled AC Drive 137X2553

VACON 

VACON NXP Air Cooled AC Drive 4 kW 380-500V IP54 - 137X2553

The VACON NXP Air Cooled AC Drive with order code 137X2553 and type code NXP00095-G5T1SSV-A1A2B500E2+FL26+ASFIF125+DLCN+SPXE is a 4 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR04...
VACON NXP Air Cooled AC Drive 137X2552

VACON 

VACON NXP Air Cooled AC Drive 315 kW 380-500V IP21 - 137X2552

The VACON NXP Air Cooled AC Drive with order code 137X2552 and type code NXP05905-A2T0SSO-A100000000+ARFIFF03 is a 315 kW (450 HP), three-phase 380-500 V supply, IP21 enclosure, frame FR11...
VACON NXP Air Cooled AC Drive 137X2547

VACON 

VACON NXP Air Cooled AC Drive 11 kW 380-500V IP21 - 137X2547

The VACON NXP Air Cooled AC Drive with order code 137X2547 and type code NXP00225-A2H1SSV-A1A3B40000 is a 11 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR05 configuration. It is rated 22...
VACON NXP Air Cooled AC Drive 137X2543

VACON 

VACON NXP Air Cooled AC Drive 400 kW 380-500V IP00 - 137X2543

The VACON NXP Air Cooled AC Drive with order code 137X2543 and type code NXP07305-G0T0SSG-A8A3000000+FL26+DLCN+GACS is a 400 kW, three-phase 380-500 V supply, IP00 enclosure, frame FR11 configuration...
VACON NXP Air Cooled AC Drive 137X2538

VACON 

VACON NXP Air Cooled AC Drive 132 kW 380-500V IP21 - 137X2538

The VACON NXP Air Cooled AC Drive with order code 137X2538 and type code NXP02615-G2T0SSG-A8A200E200+FL26+DPAP is a 132 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR09 configuration. It...
VACON NXP Air Cooled AC Drive 137X2531

VACON 

VACON NXP Air Cooled AC Drive 4 kW 380-500V IP21 - 137X2531

The VACON NXP Air Cooled AC Drive with order code 137X2531 and type code NXP00095-A2T1SSV-A1A2000000+DPAP is a 4 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR04 configuration. It is...
VACON NXP Air Cooled AC Drive 137X2532

VACON 

VACON NXP Air Cooled AC Drive 200 kW 380-500V IP54 - 137X2532

The VACON NXP Air Cooled AC Drive with order code 137X2532 and type code NXP03855-A5T0SSB-A1A2000000+FL25+LS60+DPAP+DLES is a 200 kW, three-phase 380-500 V supply, IP54 enclosure, frame FR10...
  • Previous
  • 476
  • 477
  • 478
  • 479
  • 480
  • 481
  • 482
  • 483
  • 484
  • 485
  • 486
  • Next