  • Search

VACON NXP

  • Home
  • Vacon Drives
  • VACON NXP

VACON NXP

VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Common DC Bus Rectifier Unit 137L7022

VACON 

VACON NXP Common DC Bus Rectifier Unit 650 A 525-690V IP00 - 137L7022

The VACON NXP Common DC Bus rectifier unit with order code 137L7022 and type code NXN06506-X0T0SSV-0000000000+DNOT+GNUL+GNCT+GNKC+GNUA+GNEA is a 650 A, three-phase 525-690 V supply, IP00 enclosure,...
VACON NXP Common DC Bus Active Front End Unit 137L6701

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137L6701

The VACON NXP Common DC Bus active front end unit with order code 137L6701 and type code NXA02615-G0T02SG-A1A2D7B500+ARFIF106 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137L6988

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137L6988

The VACON NXP Common DC Bus brake chopper unit with order code 137L6988 and type code NXB02086-G0T08SG-A8A3A500E2+GADN is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137L6702

VACON 

VACON NXP Common DC Bus Active Front End Unit 138 kW 380-500V IP00 - 137L6702

The VACON NXP Common DC Bus active front end unit with order code 137L6702 and type code NXA02055-G0T02SG-A1A2D7B500+ARFIF106 is a 138 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137L6700

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137L6700

The VACON NXP Common DC Bus brake chopper unit with order code 137L6700 and type code NXB00315-G2T08SV-0000000000+FL26+DLCN is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06...
VACON NXP Common DC Bus Active Front End Unit 137L6441

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 137L6441

The VACON NXP Common DC Bus active front end unit with order code 137L6441 and type code NXA11505-A0T02SG-A1A20000E9+ARFIFF05+DLES is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137L6439

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137L6439

The VACON NXP Common DC Bus brake chopper unit with order code 137L6439 and type code NXB00455-A2T08SV-A1A200BHE9 is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame FR06 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137L6362

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L6362

The VACON NXP Common DC Bus active front end unit with order code 137L6362 and type code NXA04605-A0T02SG-A1A2000000+ARFIFF05+LPC2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137L6317

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137L6317

The VACON NXP Common DC Bus active front end unit with order code 137L6317 and type code NXA04605-A0T02SG-A1A2000000+ARFIF106+LPC2 is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137L6296

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137L6296

The VACON NXP Common DC Bus active front end unit with order code 137L6296 and type code NXA02615-A0T02SG-A1A20000E3 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Brake Chopper Unit 137L6194

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137L6194

The VACON NXP Common DC Bus brake chopper unit with order code 137L6194 and type code NXB03856-A0T08SG-A1AF00D2E5 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137L6280

VACON 

VACON NXP Common DC Bus Active Front End Unit 1194 kW 525-690V IP00 - 137L6280

The VACON NXP Common DC Bus active front end unit with order code 137L6280 and type code NXA10306-A0T02SG-A1A2B5D2EA+FL23+ARFIFF05+DLDE+LPC2 is a 1194 kW, three-phase 525-690 V supply, IP00...