<
<
  • Search

VACON NXP

  • Home
  • Vacon Drives
  • VACON NXP

VACON NXP

VACONĀ® NXP is the high-performance drive platform for demanding industrial, marine and energy applications: air-cooled and liquid-cooled frequency converters, common DC bus modules, grid converters and DC/DC converters from 0.55 kW to 5.3 MW.

VACONĀ® NXP Air Cooled: technical overview

Precise and powerful performance

VACON® NXP Air Cooled drives offer precision and power to applications that require a robust and dynamic performance. Available in a complete power range up to 2 MW, they are provided as wall-mounted, standalone enclosed and IP00 modules.

The drives provide optimized motor control for both induction and permanent magnet motors, and gearless drive applications and paralleling solutions for high-power motors. Fast fieldbus options and exceptional programming flexibility ensure the drives are easily integrated into any plant’s automation system. Engineering time and costs can be saved due to the high number of standardized options and reduced system complexity.

 

Supply voltages and power range

3 x 208-240 V...0.55-90 kW
3 x 380-500 V...1.5-1200 kW 
      with DriveSynch 1.5-4000 kW
3 x 525-690 V...2.0-2000 kW
      with DriveSynch 2.0-4500 kW

 

Features and benefits

  • Easy integration into any plant’s automation system thanks to fast fieldbus options and exceptional programming flexibility
  • Investment costs are minimized as no additional external modules are needed and the drives are supplied with five built-in expansion slots for additional I/O, fieldbus and functional safety boards
  • Fast response to changes due to dynamic open- and closed-loop vector control
  • The drive’s DC fans fulfill the ERP2015 directive on decreasing fan losses and significantly increase the reliability and lifetime of the fan 
  • The lifetime of the drive and critical components are extended as a result of coated printed circuit boards that offer reliable protection against dust and moisture

 

Applications

Elevators, escalators, cranes, hoists, winches, cargo pumps, pumps, fans, conveyors, machine tools, yaw and pitch control applications, oil pumps, winders and unwinders, pulp dryers, tissue machinery and extruders.

Sub Categories

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 208-240 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 380-500 V

VACON NXP Air Cooled 525-690 V

VACON NXP Air Cooled 525-690 V

VACON NXP Common DC Bus

VACON NXP Common DC Bus

VACON NXP DC/DC Converter

VACON NXP DC/DC Converter

VACON NXP Grid Converter

VACON NXP Grid Converter

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled

VACON NXP Liquid Cooled Common DC Bus

VACON NXP Liquid Cooled Common DC Bus

View as:
Sidebar
VACON NXP Common DC Bus Active Front End Unit 137X2149

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137X2149

The VACON NXP Common DC Bus active front end unit with order code 137X2149 and type code NXA02615-A0T02SO-A1A2000000+FL25+LS60+DLES is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137X2148

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137X2148

The VACON NXP Common DC Bus active front end unit with order code 137X2148 and type code NXA02615-A0T02SO-A1A2000000+FL25+LS60 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI09...
VACON NXP Common DC Bus Active Front End Unit 137X2006

VACON 

VACON NXP Common DC Bus Active Front End Unit 259 kW 380-500V IP00 - 137X2006

The VACON NXP Common DC Bus active front end unit with order code 137X2006 and type code NXA03855-A0T02SG-A1A20000E9 is a 259 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Brake Chopper Unit 137X2041

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP00 - 137X2041

The VACON NXP Common DC Bus brake chopper unit with order code 137X2041 and type code NXB04605-A0T08SG-A1A2BH00E9 is a 2 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137X1892

VACON 

VACON NXP Common DC Bus Active Front End Unit 175 kW 380-500V IP00 - 137X1892

The VACON NXP Common DC Bus active front end unit with order code 137X1892 and type code NXA02615-A0T02SG-A1A2D70000+GRID+ARFIF106 is a 175 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137X0051

VACON 

VACON NXP Common DC Bus Active Front End Unit 377 kW 525-690V IP00 - 137X0051

The VACON NXP Common DC Bus active front end unit with order code 137X0051 and type code NXA03256-A0T02SG-A1A2B50000+FL23+DLDE+LPC2 is a 377 kW, three-phase 525-690 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137U9891

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 380-500V IP21 - 137U9891

The VACON NXP Common DC Bus brake chopper unit with order code 137U9891 and type code NXB01405-A2T08SV-A1A2000000+QGLM+FL25+LS60+DLES is a 2 kW, three-phase 380-500 V supply, IP21 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137X0650

VACON 

VACON NXP Common DC Bus Active Front End Unit 773 kW 380-500V IP00 - 137X0650

The VACON NXP Common DC Bus active front end unit with order code 137X0650 and type code NXA11505-G0T02SG-A1A2B500E9+ARFIF106+DLCN is a 773 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Brake Chopper Unit 137X1300

VACON 

VACON NXP Common DC Bus Brake Chopper Unit 2 kW 525-690V IP00 - 137X1300

The VACON NXP Common DC Bus brake chopper unit with order code 137X1300 and type code NXB01006-A0T08SV-A1A2000000 is a 2 kW, three-phase 525-690 V supply, IP00 enclosure, frame FR08 configuration. It...
VACON NXP Common DC Bus Active Front End Unit 137X0335

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137X0335

The VACON NXP Common DC Bus active front end unit with order code 137X0335 and type code NXA04605-A0T02SG-A1A200D2E3+GSSE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame FI10...
VACON NXP Common DC Bus Active Front End Unit 137X1177

VACON 

VACON NXP Common DC Bus Active Front End Unit 114 kW 380-500V IP00 - 137X1177

The VACON NXP Common DC Bus active front end unit with order code 137X1177 and type code NXA01685-A0T02SG-A8AFD700EA+UGRD+ARFIF106 is a 114 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
VACON NXP Common DC Bus Active Front End Unit 137U9833

VACON 

VACON NXP Common DC Bus Active Front End Unit 309 kW 380-500V IP00 - 137U9833

The VACON NXP Common DC Bus active front end unit with order code 137U9833 and type code NXA04605-G0T02SG-A1A2B50000+GSNT+GADN+SPXE is a 309 kW, three-phase 380-500 V supply, IP00 enclosure, frame...
  • Previous
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • Next